摘要

A simple method for Pb-210 determination in a well-type detector for matrix with apparent densities ranging from rho = 0.430 g cm(-3) to rho = 2.037 g cm(-3) is presented. Ten spiked samples of Pb-210 were prepared to obtain the detector efficiency as a quadratic function of the matrix density. Then this equation was validated and successfully used to measure Pb-210 concentration activity in other samples. The equation proposed in this work is specific for each germanium detector; however it is proposed an extrapolation of the method to other well-type germanium detector by preparing a spiked sample and determining the efficiency for Pb-210.
机译:提出了一种简单的PB-210测定的方法,其具有从rho = 0.430g cm(-3)到rho = 2.037gcm(-3)的表观密度。 制备10个PB-210的尖刺样品,以获得探测器效率作为基质密度的二次函数。 然后验证该等式并成功地用于测量其他样品中的PB-210浓度活性。 本作作品中提出的等式对每个锗探测器特异; 然而,通过制备尖刺的样品并确定PB-210的效率,提出了对其他良型锗检测器的方法的推断。