The modified New Brunswick Laboratory (NBL) Davies and Gray titrimetry method uses potassium dichromate standard 136-f from the National Institute of Standards and Technology for calibration. However, the presence of chromium in the resulting waste stream makes the disposal of waste from this procedure costly. The Actinide Analytical Chemistry (C-AAC) group at Los Alamos National Laboratory investigated and transitioned to a cerium based titrant as an alternative. We present the first long-term analytical study using this ceric-based titration method and compare it with NBL results based on the more-widely used dichromate titrimetric method.
机译:改进的新的不伦瑞克实验室(NBL)戴维斯和灰色滴定法法使用来自国家标准和技术研究所的二色素标准136-F. 然而,所得废物流中的铬的存在使得废物从该程序处置成本高昂。 Los Alamos国家实验室的Actinide分析化学(C-AAC)组研究并转变为替代品的铈滴定剂。 我们使用这种基于CERIC的滴定方法提出了第一个长期分析研究,并根据基于更广泛使用的二色素滴定法测定方法将其与NBL进行比较。