...
首页> 外文期刊>Journal of Petroleum Science & Engineering >Effect of the chromium ion diffusion in polyacrylamide/chromium acetate gelation system with surrounding water on gelation behavior
【24h】

Effect of the chromium ion diffusion in polyacrylamide/chromium acetate gelation system with surrounding water on gelation behavior

机译:铬离子扩散在聚丙烯酰胺/铬醋酸铬胶凝系统中的影响与周围水凝胶化行为

获取原文
获取原文并翻译 | 示例
           

摘要

The diffusion of Cr3+ from the Cr3+/HPAM system is simulated by quantifying the entrapment ability of the C-r3+ after dialysis analysis through a dialysis bag method to study the Cr3+ diffusion effect on the gelation types. After the gelant is put in the dialysis bag surrounded by the solvents, only the diffusion of the aqueous ions are allowed, which eventually can be detected in the dialysate. By monitoring the gelants with varying initial contents, we find that the Cr3+ dialysis kinetics and total dialyzed amount are changed. In this particular experiment, the gelation types are classified and the classification result differences for the same gelant with or without dialysis process are investigated and compared. In this study, we assess the gelant contents in terms of possible limiting scenarios for successful gelation and discuss their gelation results influenced by the Cr3+ diffusion The results demonstrate that Cr3+ diffusion, in different extent, influences the gelation types and gelation time of the Cr3+/HPAM systems with varying HPAM molecular weight (MW), the Cr3+ initial concentration, the initial HPAM polymer concentration, or the degree of initial HPAM hydrolysis. Along with the gelation types and the accompanying morphological study, determine the relationships between the initial Cr3+ concentration and the true Cr3+ concentration entrapped on the polymers are possible, which are pretty distinct from each other. Neglecting to consider such diffusion effects will lead to overestimating of the crosslinking results. In addition, a sorption model is used to demonstrate the sorption trend changes before and after the gelation time.
机译:通过量化通过透析袋方法在透析袋方法研究CR3 +扩散效应对凝胶化类型的CR3 +扩散效应来模拟CR3 + / HPAM系统的扩散。在将胶囊放入由溶剂包围的透析袋中,允许允许水性离子的扩散,其最终可以在透析液中检测。通过监测具有不同初始内容的胶脉,我们发现CR3 +透析动力学和总透析量改变。在该特定实验中,胶凝类型分类,并研究了与或不具有透析过程的相同胶粘剂的分类结果差异。在这项研究中,我们在可能的限制方案方面评估凝胶剂内容,以获得成功的凝胶化,并讨论其受Cr3 +扩散影响的凝胶化结果,结果表明CR3 +扩散在不同程度上影响CR3 + /的凝胶化类型和凝胶化时间。 HPAM系统具有不同的HPAM分子量(MW),Cr3 +初始浓度,初始HPAM聚合物浓度,或初始HPAM水解程度。随着凝胶化类型和随附的形态学研究,可以确定初始Cr3 +浓度与捕获在聚合物上的真正CR3 +浓度之间的关系,这是彼此相当截然不同的。忽视考虑这种扩散效应将导致过度估计交联结果。此外,吸附模型用于证明在凝胶化时间之前和之后的吸附趋势变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号