In this paper we apply self-optimizing control (SOC) to a cascaded LNG liquefaction plant. We first introduce the model, and then define the operational objective, which is to achieve minimal energy consumption while satisfying operational constraints. Four control structures are compared: a "standard" temperature control structure, an SOC structure with two plant measurements, an SOC structure that uses a combination of plant measurements as controlled variable, and an SOC structure where we also include measurements of disturbances in addition to the plant measurements. We find that the SOC structures significantly reduce the average steady-state loss when the operating conditions change. We furthermore find that using more plant measurements in the SOC structure results in lowered losses. In particular, for the disturbances considered, the steady-state loss becomes acceptably low, such that there is no need for a supervisory real-time optimization layer. Finally, it has been found that including disturbance measurements results in somewhat reduced losses, although the improvement was insignificant for the studied case. The effectiveness of the SOC framework is shown by closed-loop step responses to selected disturbances. (C) 2018 Elsevier Ltd. All rights reserved.
机译:在本文中,我们将自优化控制(SOC)应用于级联LNG液化厂。我们首先介绍该模型,然后定义操作目标,这是在满足操作约束的同时实现最小的能量消耗。比较四个控制结构:“标准”温度控制结构,具有两个植物测量的SOC结构,一种SOC结构,它使用植物测量的组合作为控制变量,以及我们还包括扰动的测量植物测量。我们发现SOC结构显着降低了操作条件改变时的平均稳态损耗。此外,我们发现SoC结构中的更多植物测量导致损失降低。特别地,对于所考虑的干扰,稳态损耗可接受地低,使得不需要监督实时优化层。最后,已经发现包括扰动测量结果导致损失略微降低,尽管对于所研究的情况而言是微不足道的。 SOC框架的有效性由闭环步骤响应显示为选定的干扰。 (c)2018年elestvier有限公司保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号