首页> 外文期刊>Journal of prosthodontics: official journal of the American College of Prosthodontists >Effect of Aging Time and Thickness on Low-Temperature Degradation of Dental Zirconia
【24h】

Effect of Aging Time and Thickness on Low-Temperature Degradation of Dental Zirconia

机译:老化时间和厚度对牙科氧化锆低温降解的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose To evaluate the influence of specimen thickness and low-temperature degradation (LTD) on yttrium-stabilized tetragonal zirconia polycrystals (Y-TZP). Materials and Methods Thin discs of Y-TZP from four manufacturers were sintered according to each manufacturer's recommendations, cut into 23 mm (length) x 4 mm (width) x 0.8 mm/1.5 mm (thickness) specimens, artificially aged under standard autoclave sterilization conditions (34 degrees C at 0.2 MPa for 10 and 20 hours), and finally ground and polished. Tetragonal to monoclinic transformation was confirmed by X-ray diffraction (XRD) analysis. Flexural strength was measured by 3-point bending tests and Vickers hardness measurements. Fracture surfaces were examined by scanning electron microscopy (SEM). Results SEM investigation revealed that with increasing aging time, the surface defects and grain size increased, particularly in the 20-hour group. Compared with the 1.5 mm group, the 0.8 mm group showed more significant defects, irrespective of aging time. The flexural strengths of Y-TZP materials decreased with a decrease in the thickness. Moreover, LTD of Y-TZP can cause significant tetragonal to monoclinic transformation, which also results in a statistically significant decrease in the flexural strength. Conclusion A thinner Y-TZP specimen was likely to present surface defects and microcracks after aging. In addition, the flexural strengths decreased with a decrease in the thickness, a notable fact for further studies.
机译:目的评价试样厚度和低温降解(LTD)对钇稳定四方氧化锆多晶(Y-TZP)的影响。材料和方法根据每个制造商的建议,烧结来自四种制造商的Y-TZP薄盘,切成23毫米(长)×4mm(宽度)×0.8mm / 1.5mm(厚度)标本,在标准高压釜灭菌下人工老化条件(在0.2MPa为10和20小时的34℃),最后研磨并抛光。通过X射线衍射(XRD)分析证实了四边形转化。通过3点弯曲试验和维氏硬度测量来测量弯曲强度。通过扫描电子显微镜(SEM)检查裂缝表面。结果SEM调查显示,随着老化时间的增加,表面缺陷和晶粒尺寸增加,特别是在20小时组中。与1.5mm组相比,0.8mm组呈现出更显着的缺陷,无论老化时间如何。 Y-TZP材料的弯曲强度随着厚度的降低而降低。此外,Y-TZP的有限公司可能对单斜晶型转化引起显着的四方变化,这也导致抗弯强度的统计显着降低。结论较薄的Y-TZP样品可能在老化后呈现表面缺陷和微裂纹。此外,弯曲强度随着厚度的降低而降低,对于进一步研究的显着事实。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号