首页> 外文期刊>Journal of Pharmacological and Toxicological Methods >The functional observational battery and modified Irwin test as global neurobehavioral assessments in the rat: Pharmacological validation data and a comparison of methods
【24h】

The functional observational battery and modified Irwin test as global neurobehavioral assessments in the rat: Pharmacological validation data and a comparison of methods

机译:功能性观察电池和改性Irwin测试作为大鼠的全球神经兽性评估:药理验证数据和方法比较

获取原文
获取原文并翻译 | 示例
           

摘要

Background: Evaluation of the effects of candidate drugs on the nervous system in preclinical safety pharmacology studies utilises a global neurobehavioral assessment, usually in the rat. This either takes the form of the functional observational battery (FOB) or modified Irwin Test, both of which evaluate effects across 4 functional domains: autonomic, neuromuscular, sensorimotor and behavioral. Although there is a great deal of overlap in the parameters they address, the two tests approach the assessments slightly differently. We undertook a broad pharmacological validation of both the FOB and the Irwin test, and compared the two outcomes.
机译:背景:候选药物对临床前安全药理学研究中候选药物对神经系统的影响利用全球神经兽性评估,通常在大鼠中。 这要么采用功能性观察电池(FOB)的形式或修饰的IRWIN测试,两者都评估跨4个功能域的效果:自主主义,神经肌肉,传感器和行为。 虽然它们地址的参数中存在很大的重叠,但两次测试方法略微不同地接近评估。 我们对FOB和IRWIN测试进行了广泛的药理学验证,并比较了两种结果。

著录项

  • 来源
  • 作者单位

    AstraZeneca Global Safety Assessment Alderley Pk Macclesfield SK10 4TG Cheshire England;

    AstraZeneca R&

    D Charnwood Global Safety Assessment Loughborough LE11 5RH Leics England;

    AstraZeneca Global Safety Assessment Alderley Pk Macclesfield SK10 4TG Cheshire England;

    AstraZeneca Global Safety Assessment Alderley Pk Macclesfield SK10 4TG Cheshire England;

    AstraZeneca Global Safety Assessment Alderley Pk Macclesfield SK10 4TG Cheshire England;

    AstraZeneca Global Safety Assessment Alderley Pk Macclesfield SK10 4TG Cheshire England;

    AstraZeneca Global Safety Assessment Alderley Pk Macclesfield SK10 4TG Cheshire England;

    AstraZeneca Global Safety Assessment Alderley Pk Macclesfield SK10 4TG Cheshire England;

    AstraZeneca Global Safety Assessment Alderley Pk Macclesfield SK10 4TG Cheshire England;

    AstraZeneca Global Safety Assessment Alderley Pk Macclesfield SK10 4TG Cheshire England;

    AstraZeneca Global Safety Assessment Alderley Pk Macclesfield SK10 4TG Cheshire England;

    AstraZeneca Global Safety Assessment Alderley Pk Macclesfield SK10 4TG Cheshire England;

    AstraZeneca BioPharmaceut R&

    D Discovery Sci Data Sci &

    Quantitat Biol Cambridge CB4 0WG England;

    AstraZeneca Global Safety Assessment Alderley Pk Macclesfield SK10 4TG Cheshire England;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 药理学;
  • 关键词

    ICH S7A; Core battery; Functional observational battery; Irwin test; Rat; Safety pharmacology;