Lymphoscintigraphy is an imaging technique to diagnose and characterize the severity of edema in the upper and lower extremities. In lymphoscintigraphy, a scoring system can increase the ability to differentiate between diagnoses, but the use of any scoring system requires sufficient reliability. Our aim was to determine the inter- and intraobserver reliability of a proposed scoring system for visual interpretation of lympho-scintigrams of the lower extremities. Methods: The lympho-scintigrams of 81 persons were randomly selected from our database for retrospective evaluation. Two nuclear medicine physicians scored these scans according to the 8 criteria of a proposed scoring system for visual interpretation of lympho-scintigrams of the lower extremities. Each scan was scored twice 3 mo apart. The total score was the sum of the scores for all criteria, with a potential range of 0 (normal lymphatic drainage) to 58 (severe lymphatic impairment). The intra- and interobserver reliability of the scoring system was determined using the Wilcoxon signed-rank test, percentage of agreement, weighted k, and intraclass correlation coefficient with 95% confidence interval. In addition, for 7 categories, differences in total scores between and within observers were determined. Results: We found some insignificant differences between observers. Percentage agreement was high or very high, at 82.7%-99.4% between observers and 84.6%-99.4% within observers. For each criterion of the scoring system, the K-cor-relations showed moderate to very good inter- or intraobserver reliability. The total scores for all criteria had good inter- and intraobserver reliability. Regarding the interobserver comparison, 66% and 64% of the difference in total scores were within ±1 scale point (-1, +1), and regarding the intraobserver comparison, 68% and 72% of the difference in total scores were within ±1 scale point. Conclusion: The proposed scoring system is a reliable tool for visual qualitative evaluation of lymph transport problems in patients with lymphedema of the lower extremities.
机译:Lymphoscintigraphy是一种诊断和表征上肢和下肢水肿严重程度的成像技术。在淋巴动物上,评分系统可以增加区分诊断的能力,但是使用任何评分系统的使用需要足够的可靠性。我们的目的是确定一个提出的评分系统的互联网服务器可靠性,以便对下肢的淋巴闪烁术的视觉解释。方法:从我们的数据库中随机选择81人的Lympho-scintigram以进行回顾性评估。两种核医学医生根据提出的评分系统的8个标准对这些扫描进行了评分,用于视觉解释下肢的淋巴闪烁扫描。每次扫描都均分为两次。总分是所有标准的分数总和,潜在范围为0(正常淋巴引流)至58(严重淋巴损伤)。使用Wilcoxon签名 - 等级测试,协议,加权k和腹部相关系数的百分之一体确定评分系统的内杂交和interobserver可靠性,具有95%置信区间。此外,对于7个类别,确定观察者之间的总分数分数的差异。结果:我们发现观察者之间的一些微不足道的差异。百分比协议高或非常高,观察者之间的82.7%-99.4%,观察员内的84.6%-99.4%。对于评分系统的每个标准,K-COR-关系显示中等至非常好的间或垄断服务器可靠性。所有标准的总分数都具有良好的和陷入内的可靠性。关于Interobserver比较,总分数的66%和64%的差异在±1比分(-1,+1)范围内,并且关于intraobserver比较,总分中的68%和72%的差异在± 1比例点。结论:所提出的评分系统是下肢淋巴瘤患者淋巴迁移问题的可靠性评价可靠的工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号