Open web steel joists (OWSJs) are prefabricated lightweight roof structure components that are designed for conventional loads in accordance with current standards and specifications. The resistance function currently used to design joists against blast loading is linearly elastic and perfectly plastic after the elastic deflection limit, which does not account for the different failure mechanisms of the joist components and system. For blast analysis and design of such roof trusses, further investigation of the behavior of these joists is needed. This paper presents numerical modeling and experimental evaluation of three different steel joist systems to failure to develop an accurate representation of the static resistance and energy absorption capabilities of OWSJ roof trusses to failure. Experimental results were used to verify robust explicit numerical models for predicting the static resistance function of OWSJ roof trusses. A deformable weld behavior was used to simulate all spot welds connecting web members to the joist top and bottom chords. Additionally, a criterion that predicts the failure of the end connection bearing seat of the joist system was included in the numerical simulation. The results of the numerical modeling and the experimental evaluation demonstrate the inadequacy of the current resistance models used for blast analysis purposes based on energy comparisons using various damage levels. (C) 2017 American Society of Civil Engineers.
机译:开放式钢丝钢托梁(OWSJS)是预制的轻质屋顶结构组件,其根据当前标准和规格设计用于传统负载。目前用于设计托梁的电阻函数在弹性偏转限制之后是线性弹性和完美的塑料,这不考虑托梁部件和系统的不同故障机制。对于这种屋顶桁架的爆炸分析和设计,需要进一步调查这些托梁的行为。本文介绍了三种不同钢托梁系统的数值建模和实验评价,未能开发奥尔屋顶桁架静态电阻和能量吸收能力的准确表示。实验结果用于验证鲁棒的明确数值模型,用于预测OWSJ屋顶桁架的静电抗性功能。可变形的焊接行为用于模拟连接腹板构件到托梁顶部和底部弦的所有点焊。另外,在数值模拟中包括预测托托系统的端部连接轴承座的故障的标准。数值建模的结果和实验评估证明了基于使用各种损伤水平的能量比较的用于爆炸分析目的的电阻模型的不足。 (c)2017美国土木工程师协会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号