In 2004, during ordinary maintenance work, consisting of waterproofing a building located in the south of Italy, the long-span (14.5 m) in situ RC roof partially collapsed. The building, constructed in 1950, was in service as a cinema until 1967 and then utilized as a school until 1985. Lastly, it was a hotel until 2000. In 2004, when the building was not in service and was undergoing maintenance work, it partially collapsed under dead load. After the collapse, which involved a large portion of the roof, several beams, and two columns, the Italian court nominated an official technical consultant to investigate the direct and related causes of the failure. After the main causes were identified, the building was repaired and the roof was reconstructed with a light steel structure. This article is focused on the behavior of the collapsed structure considering the original design choices, the construction details adopted, and the material properties, including the effect of concrete and steel degradation. The influences of these aspects on the collapse are examined, with particular emphasis on concrete carbonation, steel bar corrosion, and design mistakes. The lessons learned from the case study could help professional engineers to be aware of the main peculiarities and structural deficiencies of structural systems affected by material degradation and the importance of in situ periodic checks and monitoring during the life of the structures.
机译:2004年,在普通的维护工作期间,由位于意大利南部的建筑物的防水,长期(14.5米)的原位RC屋顶部分坍塌。 1950年建造的建筑物作为电影院,直到1967年作为一所学校,直到1985年。最后,它是一家酒店,直到2000年。2004年,当建筑物不在服务并且正在进行维护工作时,它在载荷下部分塌陷。崩溃后,涉及大部分屋顶,几个梁和两列,意大利法院提名官方技术顾问来调查失败的直接和相关原因。识别出主要原因后,修复了建筑物,并用轻钢结构重建屋顶。本文专注于考虑原始设计选择的折叠结构的行为,采用的施工细节和材料特性,包括混凝土和钢化降解的效果。检查这些方面对崩塌的影响,特别强调混凝土碳化,钢筋腐蚀和设计错误。从案例研究中汲取的经验教训可以帮助专业工程师意识到受重大劣化影响的结构系统的主要特点和结构缺陷,以及在结构期间原位定期检查和监测的重要性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号