首页> 外文期刊>Journal of Neuroscience Methods >An examination of the linearity and reliability of the electromyographic amplitude versus dynamic constant external resistance relationships using monopolar and bipolar recording methods
【24h】

An examination of the linearity and reliability of the electromyographic amplitude versus dynamic constant external resistance relationships using monopolar and bipolar recording methods

机译:使用单极和双极记录方法检查电拍摄幅度与动态恒定外部电阻关系的线性度和可靠性

获取原文
获取原文并翻译 | 示例
       

摘要

The purpose of this study was to examine the linearity and reliability of the electromyographic (EMG) amplitude versus dynamic constant external resistance (DCER) relationships for monopolar and bipolar recording techniques during concentric and eccentric muscle actions. Nineteen healthy men (mean +/- SD age = 22.9 +/- 2.5 years) performed a series of randomly ordered, submaximal to maximal, unilateral DCER muscle actions of the dominant forearm flexors on two occasions separated by at least 48 h. Specifically, the subjects lifted and lowered weights corresponding to 10-100% of the one repetition maximum (1-RM) in 10% increments. During each muscle action, monopolar and bipolar surface EMG signals were detected simultaneously from the biceps brachii. For the monopolar and bipolar methods, the coefficients of determination for the EMG amplitude versus DCER relationships ranged from 0.64-0.98 and 0.38-0.98 for the concentric muscle actions and 0.45-0.98 and 0.45-0.98 for the eccentric muscle actions, respectively. The intraclass correlation coefficients (ICC) and corresponding standard errors of measurement (SEM) for the linear slope coefficients for the EMG amplitude versus DCER relationships were 0.682 (18.4%) and 0.594 (21.8%) with the monopolar method and 0.810 (25.6%) and 0.774 (17.6%) with the bipolar method for the concentric and eccentric muscle actions, respectively. These findings indicated that monopolar and bipolar recording techniques may be used with a similar degree of linearity and reliability for the EMG amplitude versus concentric and eccentric DCER relationships. (C) 2010 Elsevier B.V. All rights reserved.
机译:本研究的目的是检查同心和偏心肌动作期间对单极和双极记录技术的电偏心(EMG)振幅与动态恒定外部电阻(DCER)关系的线性度和可靠性。十九个健康的男性(平均+/- SD = 22.9 +/- 2.5年)进行了一系列随机订购的潜艇到最大,单侧蜗杆肌动作,两次分开至少48小时。具体而言,受试者以10%的增量提升和降低对应于10-100%的重复(1-RM)的重量。在每种肌肉作用期间,从二头肌Brachii同时检测单极和双极表面EMG信号。对于单极和双极方法,EMG振幅的测定系数分别为同心肌肉作用的0.64-0.98和0.38-0.98,分别用于偏心肌动作的0.45-0.98和0.45-0.98。用于EMG幅度与轻杆关系的线性斜率系数的脑内相关系数(ICC)和测量标准误差(SEM)为单位单位单位和0.594(21.8%),单极方法和0.810(25.6%) 0.774(17.6%)分别具有同心和偏心肌动作的双极方法。这些发现表明,单极和双极记录技术可以与类似程度的线性度和可靠性一起使用,以及EMG幅度与同心和偏心的轻度关系。 (c)2010年elsevier b.v.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号