Cathodic protection and DC non-stationary anodic interference

机译:阴极保护和直流非静止阳极干扰

获取原文
获取原文并翻译 | 示例

摘要

DC stray currents may induce corrosion on buried carbon steel pipelines transporting methane even if in cathodic protection. According to international standard, anodic interference is unacceptable if the IR-free potential is more positive than the protection potential (-0.85 V CSE). But, duration and magnitude of the anodic peak is not defined. This paper describes results of laboratory tests performed in soil-simulating environment on cathodically protected carbon steel specimens suffering DC interference at varying peak current density, anodic potential and duration. Measured corrosion rate is always lower than the theoretical value predicted by Faraday Law. Consequently, it is possible to conclude that cathodic protection has a positive effect towards DC interference. A parameter Time Out of Protection has been defined as the period of time during interference where the potential is more positive than -0.85 V CSE; this factor has been correlated to the measured potential during DC interference.
机译:直流杂散电流可能会对掩埋碳钢管道造成腐蚀,即使在阴极保护中也可以诱导运输甲烷。根据国际标准,如果无红潜力比保护电位(-0.85 v CSE)更积极,阳极干扰是不可接受的。但是,未定义阳极峰的持续时间和大小。本文介绍了在不同峰值电流密度,阳极电位和持续时间的阴极保护的碳钢样品上对土壤模拟环境进行的实验室测试的结果。测量的腐蚀速率始终低于法拉第法预测的理论值。因此,可以得出结论,阴极保护对DC干扰具有积极影响。保护的参数时间被定义为干扰期间的时间段,其中电位比-0.85 V CSE更积极;该因子与DC干扰期间的测量电位相关联。