This study herein presents investigations about behavior of circular flange bolted connection (CFBC) in ultra high performance fiber reinforced concrete (UHPFRC) hollow segmented communication tower subjected to lateral dynamic load. The CFBC consists of two flanged concrete, cast together with the structural segment tubes and then connected using steel bolts. The paper is illustrated with CFBC joint of 500mm flange thicknesses, and 8M25 high strength steel bolts coming from a typical real design tower. For this purpose, the full scale CFBC joints for communication tower are made from Ultra High Performance Fiber Reinforced Concrete (UHPFRC). The connection was cast and experimentally tested by applying cyclic lateral load using dynamic actuator. The lateral strength and stiffness resistance of the UHPFRC CFB connections were evaluated in this study. Besides, a rigorous FEM analysis was executed in order to evaluate the performance of CFBC in the communication tower by investigating the mechanism of force transfer, load bearing capacity as well as failure behavior of the circular flange bolted connection (CFBC) under lateral cycling loading. The experimental and numerical analysis results showed the ability of UHPFRC circular bolted connection to resist the applied lateral loads. In addition, the considered model revealed that for joints under tension, bolts were seriously not subjected to bending moments which is due to the prying effect. This was made possible by the provision of adequate flange thickness and strength of the UHPFRC material.
机译:本发明的研究介绍了对超高性能纤维钢筋混凝土(UHPFRC)中空分段通信塔的圆形法兰螺栓连接(CFBC)的行为的调查。 CFBC由两个法兰混凝土组成,与结构段管一起铸造,然后使用钢螺栓连接。本文用500mm法兰厚度的CFBC接头和来自典型真实设计塔的8M25高强度钢螺栓进行说明。为此目的,通信塔的全规模CFBC接头由超高性能纤维混凝土(UHPFRC)制成。通过使用动态致动器施加循环横向载荷来施放连接和实验测试。在该研究中评估了UHPFRC CFB连接的横向强度和刚度抗性。此外,执行了严格的有限元分析,以便通过研究横向循环负载下圆形法兰螺栓连接(CFBC)的圆形法兰螺栓连接(CFBC)的失效行为来评估CFBC在通信塔中的性能。实验性和数值分析结果表明UHPFRC圆形螺栓连接能力抵抗施加的侧向载荷。此外,所考虑的模型表明,对于张力下的关节,螺栓严重不受弯曲的瞬间,这是由于撬动效应。通过提供足够的法兰厚度和UHPFRC材料的强度来实现这一点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号