...
首页> 外文期刊>Journal of near infrared spectroscopy >Effect of waxy material and measurement position of a sugarcane stalk on the rapid determination of Pol value using a portable near infrared instrument
【24h】

Effect of waxy material and measurement position of a sugarcane stalk on the rapid determination of Pol value using a portable near infrared instrument

机译:甘蔗秸秆蜡状物料和测量位置对使用便携式近红外仪器快速测定POM值的影响

获取原文
获取原文并翻译 | 示例
           

摘要

Near infrared spectroscopy can be applied as a rapid and non-destructive method for monitoring sugarcane quality after determining the precision and accuracy of the approach and model to be used for evaluating stems. In this study, near infrared spectroscopy has been applied to breeding management systems and commercial sugar production. Near infrared spectra were collected using a portable near infrared instrument incorporating a wavelength region of 730-1000 nm. To achieve an effective sampling technique, the investigated cane samples included stems with original cane surface and stems with cane wax removed surface. Results revealed that calibrations based on spectra recorded at only 1-position (1-position spectra) of original samples were poor, while calibrations based on stems with wax removed were acceptable for screening with RMSEP values of 1.2%Pol. Also, the 2-position averaged spectra of non-removed wax samples provided fair models, while 4- and 8-position averaged spectra gave good results with R-2 of 0.78-0.82, r(2) of 0.78-0.82, RMSEP of 1.2%Pol to 1.4%Pol and RPD of 2.1 to 2.4, respectively. The calibration model developed from removed-wax samples at positions 1-, 2 , 4- and 8-averaged spectra rendered effective performances with R-2 of 0.73 0.82, r(2) of 0.73 0.84, RMSEP of 1.2%Pol to 1.5%Pol and RPD of 2.1 to 2.5. Outcomes were not different in performance, even if the scanned positions and number of scans differed. Hence, the author concluded that 1-position spectra with removed-wax samples were convenient and suitable for the measurement of cane stalk Pol value.
机译:在确定用于评估茎的方法和模型的精度和准确性后,可以将近红外光谱应用作为监测甘蔗质量的快速和无损性方法。在这项研究中,近红外光谱已经应用于育种管理系统和商业糖生产。使用包含730-1000nm的波长区域的便携式近红外仪器收集近红外光谱。为了实现有效的采样技术,所研究的拐杖样品包括茎,原有的甘蔗表面,茎蜡蜡除去表面。结果表明,基于仅在原始样品的1位(1位光谱)上记录的光谱的校准差,而基于蜡的茎校准可用于筛选RMSEP值1.2%POL。此外,非去除蜡样品的2位平均光谱提供了公平的模型,而4-和8位平均光谱具有0.78-0.82,R(2)的R-2,R-2的效果良好,RMSEP 1.2%POL至1.4%POL和RPD分别为2.1至2.4。从位于1-,2,4-和8平均光谱处的校准模型在位置1-,2,4-和8平均光谱中呈现有效性能,其R-2为0.73 0.82,R(2)为0.73 0.84,RmSEP为1.2%POL至1.5% POL和RPD为2.1到2.5。结果在性能方面没有不同,即使扫描的位置和扫描的数量不同。因此,作者得出结论,用移除蜡样品的1位频谱方便,适用于甘蔗茎POL值的测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号