首页> 外文期刊>Journal of magnetic resonance imaging: JMRI >Dose‐dependence of transient respiratory motion artifacts on gadoxetic acid‐enhanced arterial phase MR images
【24h】

Dose‐dependence of transient respiratory motion artifacts on gadoxetic acid‐enhanced arterial phase MR images

机译:瞬时呼吸运动伪影对乙酰乙酸增强动脉阶段MR图像的剂量依赖性

获取原文
获取原文并翻译 | 示例

摘要

Purpose To compare the occurrence of transient respiratory motion (TM) artifacts between 0.05 mmol/kg and 0.025 mmol/kg gadoxetic‐acid on arterial phase MRI intra‐individually for evaluating dose‐dependence of gadoxetic acid. Materials and Methods This retrospective study involved 91 patients who underwent dynamic MRI at 1.5T at different times, one time with 0.05 mmol/kg and the other 0.025 mmol/kg gadoxetic‐acid. Examinations with 0.05 mmol/kg totaled 91 scans, and examinations with 0.025 mmol/kg totaled 375 scans (due to multiple exams for several patients). The scan with 0.025 mmol/kg closest in time to the 0.05 mmol/kg scan was selected to minimize temporal effects. Two radiologists graded TM artifacts in the arterial phase images using a four‐point scale: no, mild, moderate, and severe artifacts. Results were compared between the two protocols (0.05 mmol/kg versus all 0.025 mmol/kg and 0.05 mmol/kg versus selected 0.025 mmol/kg), and the odds ratio for moderate‐to‐severe artifacts was calculated. Results Significantly more TM artifacts were observed in the double dose (16/91 [17%]) scans compared with either all (17/375 [4%]; P ??0.01) or selected (3/91 [3%]; P ?=?0.01) standard dose scans. The odds ratio of the moderate‐to‐severe artifacts with the higher dose was 4.99–5.33. Conclusion There appears to be dose‐dependence of gadoxetic‐acid and the occurrence of TM artifacts. Level of Evidence: 3 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:433–438.
机译:目的,将动作呼吸运动(TM)伪像的发生在动脉期MRI中的0.05mmol / kg和0.025mmol / kg乙酰亚酸中进行,用于评估乙酰甲酸的剂量依赖性。材料和方法这种回顾性研究涉及91名患者在不同时间的1.5T处接受动态MRI,一次性含0.05mmol / kg和其他0.025mmol / kg乙酰氧基酸。用0.05mmol / kg的检查总计91次扫描,以及0.025mmol / kg的检查总计375扫描(由于几个患者的多次考试)。选择扫描与0.025mmol / kg最接近0.05mmol / kg扫描的扫描,以最小化时间效应。两个放射科医师使用四点刻度在动脉相位图像中分级TM伪影:NO,轻度,中等和严重的伪影。结果比较两种方案(0.05mmol / kg,与所有0.025mmol / kg和0.05mmol / kg相反,选择0.025mmol / kg),并且计算了中度至严重伪影的差距。结果在双剂量(16/91 [17%])扫描中观察到更明显的TM伪像与全部(17/375 [4%];p≤≤0.01)或选定(3/91 [3%] ]; p?= 0.01)标准剂量扫描。具有较高剂量的中度至严重伪影的差距为4.99-5.33。结论似乎有剂量依赖性亚酸和TM伪影的发生。证据水平:3技术疗效:第3阶段J. MANG。恢复。 2018年成像; 47:433-438。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号