Comparison of modified two‐point dixon and chemical shift encoded MRI water‐fat separation methods for fetal fat quantification

机译:修饰两点迪克松和化学换档编码的MRI水脂分离方法对胎儿脂肪量化的比较

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND Fetal fat is indicative of the energy balance within the fetus, which may be disrupted in pregnancy complications such as fetal growth restriction, macrosomia, and gestational diabetes. Water‐fat separated MRI is a technique sensitive to tissue lipid content, measured as fat fraction (FF), and can be used to accurately measure fat volumes. Modified two‐point Dixon and chemical shift encoded MRI (CSE‐MRI) are water‐fat separated MRI techniques that could be applied to imaging of fetal fat. Modified two‐point Dixon has biases present that are corrected in CSE‐MRI which may contribute to differences in the fat measurements. PURPOSE To compare the measurement of fetal fat volume and FF by modified two‐point Dixon and CSE‐MRI. STUDY TYPE Cross‐sectional study for comparison of two MRI pulse sequences. POPULATION Twenty‐one pregnant women with singleton pregnancies. FIELD STRENGTH/SEQUENCE 1.5T, modified two‐point Dixon and CSE‐MRI. ASSESSMENT Manual segmentation of total fetal fat volume and mean FF from modified 2‐point Dixon and CSE‐MRI FF images. STATISTICAL TESTS Reliability was assessed by calculating the intraclass correlation coefficient (ICC). Agreement was assessed using a one‐sample t‐test on the fat measurements difference values (modified two‐point Dixon ‐ CSE‐MRI). The difference scores were tested against a value of 0, which would indicate that the measurements were identical. RESULTS The fat volume and FF measured by modified two‐point Dixon and CSE‐MRI had excellent reliability, demonstrated by ICCs of 0.93 ( P 0.001) and 0.90 ( P 0.001), respectively. They were not in agreement, with CSE‐MRI giving mean fat volumes 180 mL greater and mean FF 3.0% smaller than modified two‐point Dixon. DATA CONCLUSION The reliability between modified two‐point Dixon and CSE‐MRI indicates that either technique can be used to compare fetal fat measurements in different participants, but they are not in agreement possibly due to uncorrected biases in modified two‐point Dixon. Level of Evidence: 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018.
机译:背景技术胎儿脂肪表明胎儿内的能量平衡,这可能在妊娠并发症中被破坏,例如胎儿生长限制,麦科瘤和妊娠期糖尿病。水脂分离的MRI是对组织脂质含量敏感的技术,测量为脂肪级分(FF),并且可用于精确测量脂肪量。改性两点达克松和化学换档编码的MRI(CSE-MRI)是水脂分离的MRI技术,可应用于胎儿脂肪的成像。修改的双点Dixon具有偏置的偏置,其在CSE-MRI中校正,这可能有助于脂肪测量的差异。目的通过改进的两点Dixon和CSE-MRI比较胎儿脂肪量和FF的测量。研究型横截面研究,用于比较两个MRI脉冲序列。人口二十一名孕妇有单身孕妇。场强/序列1.5T,改进的两点迪克森和CSE-MRI。评估手动分割总胎儿脂肪量,平均来自修饰的2点达克松和CSE-MRI FF图像的FF。通过计算腹部相关系数(ICC)来评估统计测试可靠性。使用对脂肪测量差值(修改的两点Dixon-CSE-MRI)进行一次样本T检验评估协议。差异分数针对0的值进行测试,这表明测量值相同。结果改性两点Dixon和CSE-MRI测量的脂肪体积和FF具有优异的可靠性,分别由0.93(P <0.001)和0.90(P <0.001)的ICCS证明。他们并不一致,CSE-MRI给予平均脂肪量180毫升,平均值比修饰的两点迪克松更小3.0%。数据结论修改的两点迪克松和CSE-MRI之间的可靠性表明,可以使用任何技术来比较不同参与者中的胎儿脂肪测量,但由于修改的两点迪克松的未校正偏差,它们并不是一致的。证据水平:4技术疗效:第1阶段J. MANG。恢复。 2018年成像。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号