Endoscopic closure is an essential procedure in gastrointestinal (GI) surgery, but currently it is difficult to close large defects endoscopically because of the lack of an appropriate device. Previously, we developed an endoscopic clipping device that has multifiring function and is equipped with an independent clamp. The goal of this study is to provide a new closure method with this device and 4S-modified Roeder (4SMR) slipknot. The feasibility of the closure method is examined by deploying two clips during one insertion onto the 4SMR slipknot to close a 5 cm full-thickness linear defect of an ex vivo porcine stomach from the center. Mechanical strengths of clip-knot closure and the slipknot as regards to tensioning forces are also evaluated. Specifically, the mechanical strength of the 4SMR slipknot is verified by mean peak forces to failure, while the knot is tensioning by 2.5, 5, 7.5, and 10 N force (n = 20 for each group), respectively. Experimental results indicate the clip-slipknot closure can withstand a distracting force of 6.3 +/- 5.6 N. Tensioning force has a great influence on the mechanical strength of slipknot, with the mean peak force (tensioning force) being 7.1 +/- 6.5, 16.3 +/- 9.3, 18.9 +/- 10.4, and 24.2 +/- 12.0 N, respectively. The proposed closure method can be used for large defects. Tensioning force higher than 5 N is suitable to ensure a stronger 4SMR slipknot.
机译:内窥镜闭合是胃肠道(GI)手术的基本程序,但目前由于缺乏适当的装置,因此难以在内窥镜上闭合大的缺陷。以前,我们开发了具有多学功能的内窥镜剪切装置,并配备有独立的夹具。本研究的目标是提供具有该设备的新封闭方法和4S改性罗德(4SMR)Slipknot。通过在一个插入到4SMR滑动稳定期间将两个夹子部署到4SMR滑动仪中来检查闭合方法的可行性,以闭合来自中心的5cm全厚度的线性缺陷。还评估了夹子结封闭和滑动孔的机械强度。具体地,通过平均峰值力来验证4SMR滑刺的机械强度,同时分别将结张紧为2.5,5,7.5和10N的力(每组n = 20)。实验结果表明,夹式滑移薄膜封闭可以承受6.3 +/- 5.6 n的分散注意力。张紧力对Slipknot的机械强度有很大影响,平均峰值力(张紧力)为7.1 +/- 6.5, 16.3 +/- 9.3,18.9 +/- 10.4和24.2 +/- 12.0 n。所提出的闭合方法可用于大缺陷。高于5 n的张紧力适用于确保更强的4SMR Slipknot。

著录项

  • 来源
    《Journal of Medical Devices》 |2018年第2期|共5页
  • 作者单位

    Univ Shanghai Sci &

    Technol Sch Med Instrument &

    Food Engn Shanghai 200093 Peoples R China;

    Univ Shanghai Sci &

    Technol Sch Med Instrument &

    Food Engn Shanghai 200093 Peoples R China;

    Univ Minnesota Earl E Bakken Med Devices Ctr Minneapolis MN 55455 USA;

    Univ Shanghai Sci &

    Technol Sch Med Instrument &

    Food Engn Shanghai 200093 Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 仪器、设备;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号