首页> 外文期刊>Journal of Medical Devices >Proof of Concept of a Surrogate High-Adhesion Medical Tape Using Photo-Thermal Release for Rapid and Less Painful Removal
【24h】

Proof of Concept of a Surrogate High-Adhesion Medical Tape Using Photo-Thermal Release for Rapid and Less Painful Removal

机译:使用光热释放的替代高粘合医用胶带的概念证明,可快速且较少的痛苦去除

获取原文
获取原文并翻译 | 示例
       

摘要

Medical tapes often hold critical devices to the skin so having high adhesion for the lifespan of this product is of great importance. However, the removal process is challenging for caregivers and patients alike, often a painful process that can cause medical adhesive-related skin injury (MARSI). By using an industrial thermally sensitive tape, a surrogate photosensitive tape was developed that switched from the equivalent of high-adhesion medical tape to low-adhesion medical tape. This resulted in an 86% reduction in the average peel strength when heated from 45 to 55 degrees C using a custom test apparatus. To photo-release the prototype tape (PT), a near-infrared (NIR) absorbing layer was painted on the visibly clear thermal-sensitive tape and an NIR optical wand using 15-LEDs (940 nm) with thermal feedback control was designed and tested. Preliminary performance of photo-to-thermal conversion was numerically modeled with transient results matching experimental measurements with 96.8% correspondence. Using the verified energy conversion model of the surrogate photosensitive tape, a new NIR optical wand was designed for rapid and noncontact release of a future medical tape at 10 deg lower than the release temperature (RTemp) of the custom adhesive, called UnTape. Numerical simulations compared to the thermal skin pain threshold of 45 degrees C predicts photo-release within 1.1 s of NIR exposure (85.5% absorption in PT at < 1.3 W/cm(2)). The unique properties of the multifunctional UnTape system (tape and portable NIR wand) may allow even stronger skin adhesion for critical medical devices while concurrently reducing the risk of MARSI upon photo release and easy removal.
机译:医疗胶带经常将关键装置保持在皮肤上,所以对于该产品的寿命具有很高的粘附性非常重要。然而,去除过程对护理人员和患者的挑战性,通常是一种痛苦的过程,可能导致医用粘合剂相关的皮肤损伤(MARSI)。通过使用工业的热敏胶带,开发了一种代理光敏胶带,从相当于高附加医用胶带转换为低粘附医用胶带。当使用定制测试装置将45至55摄氏度加热时,这导致平均剥离强度降低86%。为了光释放原型胶带(Pt),设计了近红外(NIR)吸收层,并设计了使用带热反馈控制的15-LED(940nm)的近红外线(NIR)吸收层。测试。光热转化的初步性能与瞬态结果匹配的实验测量值为96.8%的对应。使用替代光敏胶带的经过认证的能量转换模型,设​​计了一种新的NIR光魔魔杖,用于在10°的释放温度(RTEMP)低于定制粘合剂的释放温度(RTEMP)的快速和非接触式释放,称为Untape。与45摄氏度的热皮肤疼痛阈值相比的数值模拟预测了NIR暴露的1.1s内的光释放(在<1.3W / cm(2)中的85.5%的Pt中吸收)。多功能UNTAPE系统(胶带和便携式NIR WAND)的独特性质可以让关键医疗器械的皮肤粘附更强,同时减少照片释放后MARSI的风险,易于移除。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号