首页> 外文期刊>Journal of Low Temperature Physics >Readout of X-ray Pulses from a Single-pixel TES Microcalorimeter with Microwave Multiplexer Based on SQUIDs Directly Coupled to Resonators
【24h】

Readout of X-ray Pulses from a Single-pixel TES Microcalorimeter with Microwave Multiplexer Based on SQUIDs Directly Coupled to Resonators

机译:从单像素TES微量电流仪读出X射线脉冲,微波多路复用器基于直接耦合到谐振器的鱿鱼

获取原文
获取原文并翻译 | 示例
           

摘要

We have first demonstrated the cooperation between an X-ray TES and a directly coupled microwave SQUID multiplexer (D-coup. MW-Mux) in which SQUIDs are directly coupled to resonators. Using D-coup. MW-Mux, we successfully detected the X-ray pulses from a single-pixel TES and evaluated the energy resolution of 11.8?eV FWHM at 5.9?keV. We found this preliminary energy resolution is attributed to non-optimum bias point of the present TES, which can be improved by the future reduction of readout noise.
机译:我们首先展示了X射线TES和直接耦合微波鱿鱼多路复用器(D-COUP)之间的合作。其中鱿鱼直接耦合到谐振器。 使用D-COUP。 MW-Mux,我们成功地从单像素TES检测到X射线脉冲,并评估了11.8的能量分辨率为10.9的EV FWHM?KEV。 我们发现这种初步能量分辨率归因于当前TES的不可最大偏置点,这可以通过未来减少读出噪声来改善。