首页> 外文期刊>Journal of electromyography and kinesiology: Official journal of the International Society of Electrophysiological Kinesiology >Reproducibility of surface EMG variables in isometric sub-maximal contractions of jaw elevator muscles
【24h】

Reproducibility of surface EMG variables in isometric sub-maximal contractions of jaw elevator muscles

机译:钳口电梯肌肉等距次数收缩中表面EMG变量的再现性

获取原文
获取原文并翻译 | 示例
           

摘要

The aims of this study were: (1) to develop and assess reproducibility of a new method for measuring masticatory force in the intercuspal position; (2) to test the reproducibility of surface EMG signal amplitude and spectral variables in constant force contractions of jaw elevator muscles and its dependency on inter-electrode distance. The study was performed on the masseter and temporalis anterior muscles of both sides of nine healthy volunteers. An intraoral compressive-force sensor was used to measure maximal voluntary contraction forces in the intercuspal position and to provide a visual feedback on sub-maximal forces to the subject. Three experimental sessions were performed in three days. In each session, three isometric contractions at 80% of the maximal force were sustained by the subjects for 30 s. The intra-class correlation coefficient (ICC) of the maximal force measure was 71.9%. ICC of average rectified value and mean power spectral frequency of the EMG signal increased with inter-electrode distance, with values larger than 70% with 30 mm inter-electrode distance. It was concluded that surface EMG variables measured in isometric contractions of the jaw elevator muscles with the proposed force recording system show good reproducibility for clinical applications when a 30 mm inter-electrode distance is considered. (C) 2005 Elsevier Ltd. All rights reserved.
机译:本研究的目的是:(1)开发和评估一种用于测量骨干位置中咀嚼力的新方法的可重复性; (2)测试钳口电梯肌恒定力收缩的表面EMG信号幅度和光谱变量的再现性及其对电极间距离的依赖性。该研究是对九个健康志愿者两侧的肌等和颞型前肌的肌肉进行。用于测量内部位置中的最大自主收缩力的内部压缩力传感器,并提供对受试者的子最大力的视觉反馈。三天进行了三次实验课程。在每个会议中,80%的最大力的三个等距收缩被受试者持续30秒。最大力测量的类内相关系数(ICC)为71.9%。平均整流值的ICC和EMG信号的平均功率谱频率随电极间距离而增加,值大于70%,电极间距离为70%。得出结论是,当考虑30mm电极间距离时,钳口升降机肌肉等距收缩中测量的表面EMG变量在临床应用中显示出良好的再现性。 (c)2005年elestvier有限公司保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号