首页> 外文期刊>Journal of Electromagnetic Waves and Applications >Design considerations and experimental estimation of temperature coefficient of resistance of W-Re heater for high power pulse magnetrons
【24h】

Design considerations and experimental estimation of temperature coefficient of resistance of W-Re heater for high power pulse magnetrons

机译:高功率脉冲磁控管W-RE加热器温度系数的设计考虑与实验估计

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This paper deals with the design methodology of the heater for an indirectly-heated oxide-coated-cathode of a 3MW S-Band Pulse Magnetron. The temperature coefficient of resistance of 97%Tungsten - 3%Rhenium (W97-Re3) wire has been experimentally estimated. A value in the range of 3.07 x 10(-3) - 3.43 x 10(-3) per degrees C has been estimated over the temperature range of 863-1439 degrees C. An approach to design the heater has been evolved in order to ensure quality, reliability, and long life of high power magnetrons.
机译:本文涉及用于3MW S带脉冲磁控管的间接加热氧化涂覆阴极的加热器的设计方法。 经过实验估计97%钨 - 3%铼(W97-RE3)线的温度抗性系数。 在863-1439摄氏度的温度范围内估计了3.07×10(-3) - 3.43 x 10(-3)的值。为了 确保高功率磁控管的质量,可靠性和长寿命。