This work presents failure investigation of cooling tower fan-arms commissioned in a chemical processing plant. The analysis aims at understanding the mechanism and root-cause of the failure. The investigation involves site visits, microstructural analysis, fracture surface analysis, hardness measurements, numerical stress analysis and experimental simulation. Work concludes that the fan-arms failed due to the lack of post-weld heat treatment, which caused localized stress-corrosion and pitting at critical locations that served as crack initiation sites. Fatigue loading condition and presence of residual stresses at the weld enabled easy propagation of cracks that led to recurring premature failure. Based on the root-cause and the mechanism identified in this analysis, proper pre-heating and post-weld heat treatment is recommended to relieve the residual stresses at the critical locations and thus to avoid/minimize such recurring failures in future.
机译:这项工作提出了在化学加工厂委托的冷却塔粉丝手臂的故障调查。 分析旨在了解失败的机制和根本。 调查涉及现场参观,微观结构分析,断裂表面分析,硬度测量,数值应力分析和实验模拟。 最后的工作得出结论是,由于缺乏焊接后热处理,扇形臂失效,这导致局部应力腐蚀和在作为裂纹启动位点的关键位置进行蚀。 疲劳负载条件和焊缝处残余应力的存在使得易于传播的裂缝导致重复发生的过早失效。 基于该分析中鉴定的根本原因和机构,建议适当的预热和焊接后热处理来减轻关键位置处的残余应力,从而避免/将来最小化这种重复失效。