首页> 外文期刊>Journal of Endodontics: Official Journal of American Association of Endodontists >Do Contaminating Substances Influence the Rheological Properties of Root Canal Sealers?
【24h】

Do Contaminating Substances Influence the Rheological Properties of Root Canal Sealers?

机译:污染物质是否会影响根管密封剂的流变性质?

获取原文
获取原文并翻译 | 示例
           

摘要

Introduction: This study evaluated the effect of residual substances derived from irrigant solutions and intracanal medications on the rheological properties of a silicone, gutta-percha, and bioactive glass-based sealer in comparison with an epoxy resin-based sealer. Methods: Thin films of contaminants (0.5 mu L) (3% sodium hypochlorite [NaOCl], chlorhexidine digluconate [CHX], 17% EDTA, calcium hydroxide, 40% citric acid, or distilled water [DW]) were applied along with freshly mixed GuttaFlow Bioseal (GFB; Coltene/Whaledent, Langenau, Germany) or AH Plus Jet (Dentsply DeTrey, Konstanz, Germany) on the lower plate of a dynamic rheometer. Rheological measurements were performed in oscillating mode at the strain amplitude, angular frequency, and constant temperature of 0.01%, 10 rad/s, and 37 degrees C, respectively. Samples without contaminants served as controls. All measurements were performed 5 times. The Kolmogorov-Smirnov test and 1-way analysis of variance followed by the Student-Newman-Keuls test were performed to analyze the results (P < .05). Results: The contaminants did not alter the setting time of GFB compared with the controls; however, CHX and calcium hydroxide decreased its complex viscosity (eta*) (P < .05). The setting time of AH Plus Jet was increased by DW, CHX, citric acid, and EDTA (P < .05). All contaminants decreased its eta* at the setting point (P < .05). NaOCl led to the greatest alteration of its rheological parameters. Conclusions: Irrigant solutions and intracanal medications adversely affected at least 1 of the tested rheological properties of both sealers, except for DW and 3% NaOCl, which did not alter any rheological property of GFB.
机译:介绍:本研究评估了与环氧树脂基密封剂相比,评价衍生自洗电油溶液和骨膜药物的残留物质对硅氧烷,牙龈 - PETCHA和生物活性玻璃的流变性质的影响。方法:施用薄膜(0.5μl)(3%次氯酸钠[NaOCl],氯己定量氢酸钙,17%EDTA,氢氧化钙,40%柠檬酸或蒸馏水[DW])进行施用混合的Guttaflow生物骨髓(GFB; CONTENE / WHALENDENT,Langenau,德国)或AH Plus Jet(Lentply Detrey,Konstanz,德国)在动态流变仪的下板上。在应变幅度,角度频率和0.01%,10 rad / s和37℃的恒定温度下进行流变测量。没有污染物的样品用作对照。所有测量均进行5次。 Kolmogorov-Smirnov试验和单向差异分析,然后进行学生 - 新手龙氏试验,分析结果(P <.05)。结果:与对照相比,污染物没有改变GFB的设定时间;然而,CHX和氢氧化钙降低了其复合粘度(ETA *)(P <.05)。 DW,CHX,柠檬酸和EDTA增加AH PLUS射流的设定时间(P <.05)。所有污染物在设定点处减少其ETA *(P <.05)。 NaoCl导致其流变参数的最大变化。结论:冲洗液和骨膜药物对两种封口剂的至少1个受试者流变性质产生不利影响,除了DW和3%NoOCL,其不会改变GFB的任何流变性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号