首页> 外文期刊>Journal of computer assisted tomography >Gastrointestinal Air Motion Artifact Which Can Be Mistaken for Active Gastrointestinal Bleeding in Multidetector Computed Tomography: Phantom and Clinical Study
【24h】

Gastrointestinal Air Motion Artifact Which Can Be Mistaken for Active Gastrointestinal Bleeding in Multidetector Computed Tomography: Phantom and Clinical Study

机译:胃肠道空气运动伪影可以被误认为是多票中的活性胃肠道出血,计算机断层扫描:幻影和临床研究

获取原文
获取原文并翻译 | 示例
       

摘要

Objectives We investigated the computed tomographic characteristics of gastrointestinal air motion artifact (GIAMA), which can be misinterpreted as active gastrointestinal bleeding. Methods We simulated GIAMA using 3 types of air-ball phantoms (air-ball in water, air-ball in oil, air-water-ball in oil) and a bovine intestine in oil phantom. We also performed a retrospective clinical review of precontrast abdominal computed tomography images of 76 patients to investigate the frequency, location, shape, and maximum density of hyperdense GIAMA. Results In phantom studies, air motion artifacts appeared as dark and bright streak artifacts at the borders of a moving air-ball and water or oil. In the clinical study, hyperdense GIAMA was visualized in 60 (79.0%) of 76 patients. The small intestine was most commonly affected (46.4%), and the intramural type had the highest frequency (58.0%). Conclusion Knowing the radiologic features of GIAMA can assists radiologists in identifying active gastrointestinal bleeding sites accurately.
机译:目的我们研究了胃肠道空气运动伪影(胶质)的计算断层特征,这可以被误解为活性胃肠道出血。方法采用3种空气球幻影(水,油,油,油中的空气球,油)和油幽灵牛肠的气球模拟胶质。我们还对76名患者的预体腹部计算机断层扫描图像进行了回顾性临床审查,以研究高阵列胶质的频率,位置,形状和最大密度。结果在幻影研究中,空气运动伪影出现在移动空气球和水或油的边界处的暗和明亮的条纹伪影。在临床研究中,高阵列胶质在60例(79.0%)的76名患者中可视化。小肠最常见的影响(46.4%),内际型具有最高频率(58.0%)。结论了解胶质的放射学特征可以帮助放射科医师准确地识别活性胃肠道出血位点。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号