...
首页> 外文期刊>Journal of artificial organs: The official journal of the Japanese Society for Artificial Organs >Clampless aortic punch system for making a large-diameter access route without side-biting clamp: a preliminary study
【24h】

Clampless aortic punch system for making a large-diameter access route without side-biting clamp: a preliminary study

机译:用于制造大直径接入路线而无需侧咬夹具的丝毫主动脉冲压系统:初步研究

获取原文
获取原文并翻译 | 示例
           

摘要

Although thoracic endovascular aneurysm repair (TEVAR) has been getting popularity as a less-invasive procedure, the treatment of thoracic aortic aneurysm with atherosclerotic aortic disease is still challenging. In hybrid TEVAR through the median sternotomy approach, side-biting clamp of the ascending aorta is often necessary for making an access route; however, it could cause embolic complication and aortic dissection. This study aimed to present the results of our preliminary study on the clampless aortic punch system (APS). The swine aorta was used as experimental specimen (diameter 16-20 mm). A 10-mm collagen-impregnated knitted Dacron graft was anastomosed to the aorta, and the APS was inserted into it. After piercing the aorta with the inner fish hook of the APS, the aortic wall was scooped out by an outer round cutter. Three different-angled cutters (0 degrees, 15 degrees, and 30 degrees) were tested three times. The diameter of the punched-out lesion ranged from 6 to 9 mm (median 8 mm). Macroscopically, no major vessel injuries were seen 15 degrees series, whereas minor or major vessel injuries were seen 30 degrees and 0 degrees series, respectively. Histological findings of 15 degrees series confirmed the sharp edge of the stump and abrupt interruption of the elastic fiber without destruction of the normal three-layer structure of the aortic wall. This study suggests that our clampless APS could reduce the risk of stroke and aortic injury in hybrid TEVAR, and an animal study confirming its utility is now under consideration.
机译:虽然胸腔血管内动脉瘤修复(TEVAR)一直受到普及的较令人侵袭的手术,但胸腔主动脉瘤的治疗具有动脉粥样硬化主动脉疾病仍然具有挑战性。在杂交Tevar通过中位数术术方法,倾向于升高的主动脉夹具通常需要进行接入路线;然而,它可能导致栓塞并发症和主动脉解剖。本研究旨在展示我们对Metampless主动脉冲床系统(AP)的初步研究结果。猪主动脉用作实验标本(直径16-20mm)。将10mm的胶原浸渍针织碎代克状碎片移植物吻合到主动脉,将APS插入其中。在用AP的内部鱼钩刺穿主动脉之后,主动脉壁被外圆形刀具舀出。三次测试三个不同角度的切割器(0度,15度和30度)。打孔损伤的直径范围为6至9毫米(中位数8mm)。宏观上,没有任何主要的血管损伤是15度系列,而轻微或主要血管损伤分别被观察到30度和0度系列。 15度系列的组织学发现证实了树桩的尖锐边缘和弹性纤维的突然中断而不会破坏主动脉壁的正常三层结构。本研究表明,我们的猫咪普遍可能降低杂交Tevar中风和主动脉损伤的风险,现在正在考虑确认其实用性的动物研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号