The SCoRE residual: a quality index to assess the accuracy of joint estimations.

机译:分数残差:评估联合估计准确性的质量指标。

获取原文
获取原文并翻译 | 示例
           

摘要

The determination of an accurate centre of rotation (CoR) from skin markers is essential for the assessment of abnormal gait patterns in clinical gait analysis. Despite the many functional approaches to estimate CoRs, no non-invasive analytical determination of the error in the reconstructed joint location is currently available. The purpose of this study was therefore to verify the residual of the symmetrical centre of rotation estimation (SCoRE) as a reliable indirect measure of the error of the computed joint centre. To evaluate the SCoRE residual, numerical simulations were performed to evaluate CoR estimations at different ranges of joint motion. A statistical model was developed and used to determine the theoretical relationships among the SCoRE residual, the magnitude of the skin marker artefact, the corrections to the marker positions, and the error of the CoR estimations to the known centre of rotation. We found that the equation err=0.5r(s) provides a reliable relationship among the CoR error, err, and the scaled SCoRE residual, r(s), providing that any skin marker artefact is first minimised using the optimal common shape technique (OCST). Measurements on six healthy volunteers showed a reduction of SCoRE residual from 11 to below 6mm and therefore demonstrated consistency of the theoretical considerations and numerical simulations with the in vivo data. This study also demonstrates the significant benefit of the OCST for reducing skin marker artefact and thus for predicting the accuracy of determining joint centre positions in functional gait analysis. For the first time, this understanding of the SCoRE residual allows a measure of error in the non-invasive assessment of joint centres. This measure now enables a rapid assessment of the accuracy of the CoR as well as an estimation of the reproducibility and repeatability of skeletal motion patterns.
机译:来自皮肤标记物的精确旋转(Cor)的测定对于评估临床步态分析中的异常步态模式至关重要。尽管估算了CORS的许多功能方法,但目前不可用无侵入性分析确定重建的关节位置中的误差。因此,本研究的目的是验证对称旋转估计(得分)的对称中心的残余,作为计算的关节中心误差的可靠间接测量。为了评估得分残余,进行数值模拟,以评估不同范围的关节运动范围。开发统计模型并用于确定分数残余,皮肤标记人工制品的大小,对标记位置的校正以及已知旋转中心的误差的理论关系。我们发现等式err = 0.5r(s)在COR错误,ERR和缩放得分残差R(S)之间提供了可靠的关系,提供了首先使用最佳共同形状技术最小化任何皮肤标记艺术品( OCST)。六个健康志愿者的测量表明,从11到低于6mm的比分剩余的分数减少,因此表现出与体内数据的理论考虑和数值模拟的一致性。本研究还证明了用于减少皮肤标记人工制品的OCST的显着优点,从而预测功能性步态分析中确定关节中心位置的准确性。这是第一次理解得分残余,允许衡量联合中心的非侵入性评估中的错误。该措施现在可以快速评估COR的准确性以及骨骼运动模式的再现性和可重复性的估计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号