首页> 外文期刊>Journal of Applied Geophysics >Geoelectrical characterization with 1D VES/TDEM joint inversion in Urupes-SP region, Parana Basin: Applications to hydrogeology
【24h】

Geoelectrical characterization with 1D VES/TDEM joint inversion in Urupes-SP region, Parana Basin: Applications to hydrogeology

机译:乌鲁木区盆地的1D VES / TDEM联合反演的电气调,Parana盆地:水文地质学的应用

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Although Brazil is well known by the large rivers and the Amazon Rain Forest most cities do not have access to sufficient quantities of surface water to supply the population. Because of this 61% of Brazilian population (IBGE, 2003) depends on groundwater resources. In order to help the conscious exploration of this resource in Urupes city (Sao Paulo State) which is characterized by problems of lack of water, this research applied the transient electromagnetic method (TDEM) and Vertical Electrical Sounding (VES) for the geoelectrical characterization of the interest region. So, the objective of this work was increase the hydrogeological basis for groundwater exploitation of Bauru sedimentary aquifer and Serra Geral fractured aquifer (Parana Basin). A total of 23 TDEM and 15 VES soundings were conducted during the years of 2009, 2011 and 2012. In addition, 10 pairs of VES/IDEM soundings were acquired with coincident centers to be able to perform the joint inversion. The joint inversion technique is a promising tool, which enables to get the best of both methods, where the VES add the shallow information and TDEM the deeper one. In this work, the individual and joint inversions were performed using the "Curupira" software. After data process and inversion, the results were interpreted based on geological well information provided by the Department of Water and Electrical Power (DAEE) and the Brazilian Geological Survey (CPRM) which enabled to estimate favorable places to exploitation of water in Bauru and Serra Geral aquifers. For the Baum aquifer, the results suggest areas where thickness exceeds 100 m. In these areas, the resistivity calculated was about 20 Omega center dot m. Therefore, the sediments have been interpreted as saturated sandy clay. In the basalt layer of Serra Geral Formation, the suggested locations present resistivity values 100 Omega center dot m at similar to 200 m depth. The indicated places in sedimentary aquifer and the locations in the fr
机译:虽然巴西被大型河流所闻名,但亚马逊雨林大多数城市都无法获得足够的地表水来供应人口。由于这61%的巴西人口(IBGE,2003)取决于地下水资源。为了帮助乌鲁木城(SAO Paulo状态)在乌鲁木城(SAO Paulo)缺乏水问题中的有意识探索,这项研究应用了瞬态电磁法(TDEM)和垂直电气探测(VES)的电气表征兴趣区。因此,这项工作的目的是增加了Bauru沉积含水层的地下水开采水文地理基础和塞拉·盖拉尔骨折含水层(ParaNa Basin)。在2009年,2011年和2012年期间共进行了23个TDEM和15个VES探测。此外,收购了10对VES / IDEM探测,以巧合的中心获得能够执行联合反演。联合反演技术是一个有前途的工具,它可以获得两种方法,其中VES增加浅信息和更深的方法。在这项工作中,使用“Curupira”软件进行个人和联合逆变。在数据流程和反演之后,结果基于水和电力部(DAEE)和巴西地质调查(CPRM)提供的地质井信息来解释,这使得能够估算BAURU和SERRA GERAR的剥削水资源的有利地点含水层。对于BAUM含水层,结果表明厚度超过100米的区域。在这些区域中,计算的电阻率约为20ω中心点M。因此,沉积物被解释为饱和含沙粘土。在塞拉格拉格地层的玄武岩层中,所建议的位置存在电阻率值& 100ωimega中心的电阻率值与200米深度相似。沉积含水层的指示位置和FR的位置

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号