首页> 外文期刊>Journal of AOAC International >Determination of pesticides in apples by liquid chromatography with electrospray ionization tandem mass spectrometry and estimation of measurement uncertainty.
【24h】

Determination of pesticides in apples by liquid chromatography with electrospray ionization tandem mass spectrometry and estimation of measurement uncertainty.

机译:用电喷雾电离串联质谱法测定苹果苹果杀虫剂的测定。

获取原文
获取原文并翻译 | 示例
           

摘要

A liquid chromatography/electrospray ionization-tandem mass spectrometry (LC/ESI-MS/MS) method was developed and validated to determine 90 pesticides in apple samples. MS/MS data acquisition was achieved by applying multiple-reaction monitoring of 2 fragment ion transitions to provide a high degree of sensitivity and selectivity for both quantitation and confirmation. Matrix-matched standard calibration curves with the use of isotopically labeled standards (or a chemical analog) as internal standards were used to achieve the best accuracy for the method. Both a conventional method validation procedure and a designed experiment were applied to study the accuracy and precision of the method. A compiled computer program that provided a semiautomated procedure for handling a large number of calculations was used to calculate the overall recovery, intermediate precision, and measurement uncertainty (MU). In general, the overall recoveries from samples spiked at levels of 10, 50, and 80 micro g/kg, ranged from 60.8 to 121.1%, intermediate precision was <10%, and MUs were <30%. Poor accuracy and/or repeatability was observed for pyridate and etofenprox. The method limits of detection based on a signal-to-noise ratio of >3 were usually <1 micro g/kg (ppb), except those for aldicarb sulfoxide and pyridaphenthion, which were about 5 micro g/kg..
机译:开发液相色谱/电喷雾电离串联质谱(LC / ESI-MS / MS)方法并验证以确定苹果样品中的90种农药。通过应用2片段离子过渡的多反应监测来实现MS / MS数据采集,以提供高度灵敏度和定量和确认的选择性。矩阵匹配的标准校准曲线具有使用同位素标记的标准(或化学类似物)作为内部标准来达到该方法的最佳精度。应用传统方法验证程序和设计的实验,以研究方法的准确性和精度。编译的计算机程序,提供了用于处理大量计算的半报道过程来计算总体回收,中间精度和测量不确定性(MU)。通常,在10,50和80微米/ kg水平下掺入的样品的总回收率范围为60.8至121.1%,中间精度<10%,MU <30%。对于Pyeratiate和Etofenprox,观察到差的准确性和/或可重复性。除了用于醛杀氧基甲醚和吡吡啶硫酮的方法之外,基于> 3的信噪比的检测方法通常为<1微克峰(PPB)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号