Background: Traditional methods for Lomefloxacin hydrochloride (LOM) determination involve pretreatment steps, which extend analysis time and use hazardous chemicals. Objective: The ability to provide a rapid route without sample pretreatment for quantitative determination of compounds via a low-cost instrument is a challenging task. In this work, a simple potentiometric method was developed to determine the antibacterial LOM via in-house fabricated ion selective electrodes. Methods: Different sensors were fabricated using a poly vinyl chloride-based membrane, potassium tetrakis(4-chlorophenyl) borate as a cation exchanger, and 2-Nitrophenyl octyl ether as a plasticizer (sensor 1). To increase the selectivity of sensor 1, a selective molecular recognition component 2-hydroxypropyl-beta-cyclodextrin was used as ionophore (sensor 2). Results: The proposed method was validated according to International Union of Pure and Applied Chemistry recommendations, in which the proposed sensors show a linear dynamic range from 1 x 10(-5) to 1 x10(-2) mol/L, with Nernstian slopes of 55.829 and 58.229 mV/decade for sensors 1 and 2, respectively. It was applied to determine LOM in bulk powder, in different dosage forms, and in plasma with no sample pretreatment. Also, the suggested method can be used as a green, in-line bench top real-time analyzer for in-process monitoring of LOM release from its tablets, under U.S. Food and Drug Administration dissolution regulations, with clear discrimination from common excipients. Results obtained by the proposed potentiometric method were compared with those obtained by a reported HPLC method. Conclusions: The proposed method is considered as a perfect alternative to traditional reported methods for LOM determination.
机译:背景技术:盐酸甘油甘油甘油蛋白(LOM)测定的传统方法涉及预处理步骤,其延长分析时间并使用危险化学品。目的:通过低成本仪器提供无需样品预处理的无需样品预处理的快速路径的能力是一个具有挑战性的任务。在这项工作中,开发了一种简单的电位方法以通过内部制造的离子选择性电极测定抗菌LOM。方法:使用聚氯乙烯基膜,硼酸钾(4-氯苯基)作为阳离子交换剂,作为增塑剂(传感器1)的2-硝基苯基辛基醚制造不同的传感器。为了增加传感器1的选择性,使用选择性分子识别组分2-羟丙基-β-环糊精作为离子载体(传感器2)。结果:根据纯粹和应用化学建议的国际联盟验证了该方法,其中建议的传感器显示线性动态范围从1 x 10(5)至1 x10(-2)mol / l,内部斜坡55.829和58.229 mV /十年,分别用于传感器1和2。它被应用于以不同剂型的散装粉末测定LOM,并在不含样品预处理的血浆中。此外,建议的方法可以用作绿色的在线台面实时分析仪,用于从其片剂,在美国食品和药物管理溶解规范下从其片剂的内部监测,具有明显的常见赋形剂的歧视。将所提出的电位方法获得的结果与报告的HPLC方法获得的结果进行了比较。结论:所提出的方法被认为是传统报告的LOM测定方法的完美替代品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号