OBJECTIVE. Hydrogen-1 MR spectroscopy ( 1H-MRS) is gaining acceptance as a non-invasive technique for assessment of hepatic steatosis, and the findings have been found to correlate closely with histopathologic grade. The aims of this study were to validate 1H-MRS performed with a 3-T MRI system for quantifying hepatic steatosis and to determine threshold values of 1H-MRS proton density fat fraction corresponding to standard histopathologic grade in patients undergoing diagnostic liver biopsy. SUBJECTS AND METHODS. We conducted a prospective cross-sectional liver MRS study with 52 subjects undergoing diagnostic liver biopsy. The diagnostic accuracy of 1H-MRS was evaluated with receiver operating characteristic curves. RESULTS. The diagnostic accuracy of 1H-MRS for hepatic steatosis was high with an area under the receiver operating characteristic curve of 0.94 (95% CI, 0.88-1.0). Results were similar for three 1H-MRS measurements obtained at different locations in the liver, for two independent pathologists, and whether fibrosis was present or absent. One third of participants had elevated transaminase concentrations of unknown cause, and 1H-MRS estimates of steatosis had perfect agreement with histopathologic grade in this group. Calculated 1H-MRS proton density fat fraction thresholds for histologic grades were less than 17% for grade 0 or trace steatosis, 17-38.6% for grade 1, and greater than 38.6% for grade 2 or higher. CONCLUSION. Hydrogen-1 MR spectroscopy is an effective, noninvasive technique that can be used to diagnose and quantify hepatic steatosis. Hydrogen-1 MR spectroscopy thresholds corresponded with histopathologic grades and may be useful in the workup of patients with elevated transaminase concentrations.
机译:目的。氢1 MR光谱法(1H-MRS)作为一种非侵入性技术来评估肝脂肪变性已获得认可,并且发现与组织病理学分级密切相关。这项研究的目的是验证使用3-T MRI系统量化肝脏脂肪变性的1H-MRS,并确定与诊断性肝活检患者的标准组织病理学等级相对应的1H-MRS质子密度脂肪分数的阈值。主题和方法。我们对52位接受诊断性肝活检的受试者进行了前瞻性横断面肝脏MRS研究。 1H-MRS的诊断准确性通过接收器工作特性曲线进行评估。结果。 1H-MRS对肝脂肪变性的诊断准确性很高,接受者工作特征曲线下的面积为0.94(95%CI,0.88-1.0)。在肝脏的不同位置获得的三个1H-MRS测量结果,两个独立的病理学家获得的纤维化存在或不存在的结果相似。三分之一的参与者有未知原因的转氨酶浓度升高,并且该组中脂肪变性的1H-MRS估计与组织病理学分级完全吻合。对于组织学等级,计算得出的1H-MRS质子密度脂肪分数阈值对于0级或微量脂肪变性小于17%,对于1级为17-38.6%,对于2级或更高等级大于38.6%。结论。 Hydrogen-1 MR光谱学是一种有效的非侵入性技术,可用于诊断和量化肝脂肪变性。 Hydrogen-1 MR光谱阈值与组织病理学等级相对应,可能对转氨酶浓度升高的患者进行检查有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号