首页> 外文期刊>Hip international: the journal of clinical and experimental research on hip pathology and therapy >No effect of femoral canal jet-lavage on the stability of cementless stems in primary hip arthroplasty: a randomised RSA study with 6 years follow-up
【24h】

No effect of femoral canal jet-lavage on the stability of cementless stems in primary hip arthroplasty: a randomised RSA study with 6 years follow-up

机译:股骨管道喷射灌洗对原发性髋关节置换术粘稠茎稳定性的影响:6年随访的随机RSA研究

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Introduction: In contrast to cemented hip prostheses, the effect of washing the bone bed with jet-lavage prior to insertion of cementless stem components in primary hip arthroplasty (THA) is unclear. Jet-lavage potentially decreases the risk of fat embolisation during rasping and stem insertion and might help in avoiding bacterial contamination. An earlier animal study has shown less debris and better-organised trabecular structure of new bone when jet-lavage was used. We hypothesised that the primary stability of cementless femoral stems implanted after jet-lavage of the femoral canal prior to stem insertion would improve with earlier stabilisation, as measured with Radiostereometry (RSA), compared with insertion without prior jet-lavage. Methods: 40 patients with primary osteoarthritis operated on with a cementless titanium grit blasted stem are included in the study. The patients were randomised to either jet-lavage or control without any lavage of the femoral canal prior to insertion of the prosthesis. The stem migration pattern was measured with RSA at 0, 3, 12, 24 and 72 months. Results: At 6 years, 19 patients remained for analysis in the jet-lavage and 18 in the control group. We found no difference in extent or pattern of migration as measured with RSA. Both groups seemed to have stabilised within 3 months after a slight subsidence and retroversion. No stem was revised or considered loose as measured with RSA. Conclusions: Washing the bone bed with jet-lavage prior to insertion of cementless stems does not affect the stability of cementless femoral components. No adverse effects were observed.
机译:介绍:与粘合的髋关节假体形成鲜明对比,在初级髋关节置换术(THA)中插入粘合性茎组分之前用喷射灌洗洗涤骨床的效果。喷射灌洗可能降低腐蚀和茎插入过程中脂肪栓塞的风险,并且可能有助于避免细菌污染。当使用喷射灌洗时,早期的动物研究表明较少的碎片和更好地有组织的新骨的小梁结构。我们假设在茎插入之前植入股骨管道喷射灌洗后植入的软泥股骨茎的初级稳定性随着紫外线物测量(RSA)测量的,而不是在没有先前的喷射灌洗的情况下,与雷胶粥样物测量相比方法:在研究中包含40例患有粘土钛砂砂杆的初级骨关节炎患者。在插入假体之前,患者随机灌洗或控制,而不会在股骨管内的任何灌洗。用RSA为0,3,12,24和72个月测量茎迁移模式。结果:6岁时,19名患者在喷射灌洗和18例中持续分析。我们发现,用RSA测量的迁移范围或迁移模式没有差异。两组似乎在略微沉降和再透析后3个月内稳定。用RSA测量,没有修改茎或被认为松动。结论:在插入粘合剂茎之前用喷射灌洗洗骨床并不影响软泥股骨成分的稳定性。没有观察到不利影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号