...
首页> 外文期刊>Hand surgery: an international journal devoted to hand and upper limb surgery and related research : journal of the Asia-Pacific Federation of Societies for Surgery of the Hand >Screw Length Optimization of a Volar Locking Plate Using Three Dimensional Preoperative Planning in Distal Radius Fractures
【24h】

Screw Length Optimization of a Volar Locking Plate Using Three Dimensional Preoperative Planning in Distal Radius Fractures

机译:远端半径裂缝三维术前规划螺旋长度优化vlar锁定板

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Background: A three-dimensional (3D) digital pre-operative planning system for the osteosynthesis of distal radius fracture was developed. The objective of this study was to evaluate screw choices for three-dimensional (3D) digital pre-operative planning of osteosynthesis of distal radius fractures and to compare with the screw choices for the conventional method. Methods: Distal radius fracture patients who underwent osteosynthesis using volar locking plates were evaluated. Thirty wrists in the plan group utilized 3D preoperative planning, and nineteen wrists in the control group utilized conventional preoperative assessment. In the plan group, the 3D preoperative planning was performed prior to surgery. The reduction was simulated with 3D image, and the implant choice/placement also simulated on the 3D image. In the control group, standard preoperative planning was performed using posterior-anterior and lateral view radiographs, and CT scan. After the planning, osteosynthesis was performed. During the surgery, the operator performed the reduction and the placement of the plate while comparing images between the pre-operative plan and fluoroscopy. The distal screw lengths and the anteroposterior diameter of the radius along the axis of the distal screws were measured. The ratios of the screw length and radius diameter were evaluated. The screw/radius ratios within the range of 0.75-1.00 were considered appropriate. The screw choices less than 0.75, or greater than 1.00 were considered inappropriate. The rate of appropriate screw choices were compared between plan and control groups. Results: The results of appropriate screw choices were 86.1% and 74.8% in the plan group and the control group, respectively. The inappropriate screw choices were 14.0% and 25.2% in the plan group and the control group, respectively. The three-dimensional planning significantly increased appropriate screw choices compared to the conventional planning (p < 0.05). Conclusions: Three-dimensional digital preoperative planning is useful for the optimization of screw lengths in osteosynthesis of distal radius fractures.
机译:背景:开发了一种用于远端半径骨折的骨性合成的三维(3D)数字前术前计划系统。本研究的目的是评估远端半径骨折的骨骨合成的三维(3D)数字预术计划的螺杆选择,并与常规方法的螺杆选择进行比较。方法:评价使用Volar锁定板进行骨合成接受骨合成的远端半径骨折患者。计划团体的三十个手腕利用3D术前规划,对照组的九部手腕使用常规的术前评估。在计划组中,3D术前计划在手术前进行。用3D图像模拟还原,并且在3D图像上也模拟了植入物选择/放置。在对照组中,使用后侧和横向视图进行射线照相和CT扫描进行标准术前规划。计划后,进行骨质合成。在手术期间,操作员在比较预防计划和荧光透视之间的图像的同时执行板的减小和放置。测量远端螺钉长度和沿远端螺钉的轴线的半径的前后直径。评估螺杆长度和半径直径的比率。 0.75-1.00范围内的螺钉/半径比被认为是合适的。螺杆选项小于0.75,或大于1.00被认为是不恰当的。在计划和对照组之间比较适当的螺杆选择速度。结果:计划组和对照组的适当螺杆选择的结果分别为86.1%和74.8%。计划组和对照组的不当螺杆选择分别为14.0%和25.2%。与传统规划相比,三维规划显着提高了适当的螺杆选择(P <0.05)。结论:三维数字术前规划对于远端半径裂缝骨质合成中的螺杆长度的优化是有用的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号