首页> 外文期刊>The International journal of periodontics & restorative dentistry >Minimally Invasive Sinus Augmentation Procedure Using a Dedicated Hydraulic Sinus Lift Implant Device: A Prospective Case Series Study on Clinical, Radiologic, and Patient-Centered Outcomes
【24h】

Minimally Invasive Sinus Augmentation Procedure Using a Dedicated Hydraulic Sinus Lift Implant Device: A Prospective Case Series Study on Clinical, Radiologic, and Patient-Centered Outcomes

机译:使用专用液压窦升降植入装置的微创鼻窦增强程序:临床,放射学和以患者为中心的结果的前瞻性案例序列研究

获取原文
获取原文并翻译 | 示例
       

摘要

The aim of this study was to evaluate clinical and radiologic outcomes of a novel device that allows simultaneous hydraulic sinus membrane elevation, bone grafting, and implant placement. A sample of 18 consecutive participants with severe atrophy of the posterior maxilla underwent transcrestal elevation of the sinus membrane and implant placement. At the 6-month follow-up, the following parameters were assessed: implant success, any complications, marginal bone loss (MBL), threedimensional (3D) graft measurements, implant stability quotient (ISQ), and graft density. No implants failed during follow-up (10.8 +/- 2.8 months; range: 7-14 months). No membrane tears or other adverse events were observed. Mean residual alveolar ridge height was 4.78 +/- 0.88 mm(2). Six months after the procedure, the mean MBL was 0.18 mm(2). The mean sinus membrane elevation was 12.78 +/- 2.18 mm(2) (range: 10.7-14.23). Along the basic 3D reference planes, the dimensions of grafted bone measured around implants were as follows: axial area = 239.7 +/- 5768 mm(2); sagittal area = 2570 +/- 60.83 mm(2); coronal area = 143.3 +/- 29.46 mm(2). The mean volume of the graft was 2.38 +/- 0.26 mL at baseline and 2.05 +/- 0.24 mL 6 months after graft maturation (difference: 0.33 +/- 0.29 mL, P =.0090). Graft density (in Hounsfield units [HU]), improved during healing from 322.0 +/- 100.42 HU to 1,062.0 +/- 293.7 HU; difference 740.0 +/- 295.35 HU (P =.0001). The mean ISQ value was 65.5 at implant placement, and it increased to 74.1 at the 6-month examination (P =.0014). Of 18 patients, 12 experienced no pain (66.6%) and 10 experienced no swelling (55.5%). No severe pain or swelling was reported in any of the cases. The mean number of analgesic tablets consumed was 0.78 +/- 0.67 Mean surgical time was 24.0 +/- 4.07 minutes. The iRaise Sinus Lift System may provide a new option for minimally invasive transcrestal sinus surgery with minimal patient discomfort. A physiologic contraction of 13.9% of its original volume was experienced during healing. Long-term clinical studies are needed to confirm these preliminary results.
机译:本研究的目的是评估一种新颖的装置的临床和放射学结果,该新型装置允许同时液压窦膜抬高,骨移植和植入物放置。一种具有严重萎缩的18名参与者的样品,后颌蓟患者进行了鼻窦膜和植入物放置。在6个月的随访中,评估以下参数:植入物成功,任何并发症,边际骨丢失(MBL),三维(3D)移植物测量,植入物稳定价(ISQ)和移植物密度。随访期间没有植入物(10.8 +/- 2.8个月;范围:7-14个月)。没有观察到膜撕裂或其他不良事件。平均残留的肺泡脊高度为4.78 +/- 0.88 mm(2)。手术后六个月,平均MBL为0.18毫米(2)。平均鼻窦膜升高为12.78 +/- 2.18 mm(2)(范围:10.7-14.23)。沿着基本的3D参考平面,周围测量的植入物的接枝骨的尺寸如下:轴向区域= 239.7 +/- 5768mm(2);矢状面积= 2570 +/- 60.83 mm(2);冠状面积= 143.3 +/- 29.46 mm(2)。接枝的平均体积为2.38 +/- 0.26ml,在接枝成熟后6个月内为2.05 +/- 0.24ml(差异:0.33 +/- 0.29ml,p = .0090)。移植物密度(在Hounsfield单位[hu]),从322.0 +/-100.42胡愈合期间改善了1,062.0 +/- 293.7胡;差异740.0 +/- 295.35胡(p = .0001)。植入物放置的平均ISQ值为65.5,在6个月的检查中增加到74.1(P = .0014)。 18例患者,12名患者没有疼痛(66.6%)和10个没有肿胀(55.5%)。在任何情况下都没有报告严重的疼痛或肿胀。所消耗的镇痛片的平均数量为0.78 +/- 0.67平均手术时间为24.0 +/- 4.07分钟。反式窦提升系统可以为微创型颅骨窦手术提供新的选择,患者不适。在愈合期间经历了13.9%的原始体积的生理收缩。需要长期临床研究来确认这些初步结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号