A technology called Trace Registration (TR) has been introduced to allow dynamic navigation of implant placement without the need for a thermoplastic stent. This study was undertaken in order to validate the accuracy of the TR protocol for dynamically guided implant surgery. A retrospective, observational, in vivo study was performed using dynamic navigation via the TR protocol. The preoperative cone beam computed tomography (CBCT) plan was superimposed and registered (aligned) with the postoperative CBCT scan to assess accuracy parameters. A total of 136 implants were placed in 59 partially edentulous arches. Mean deviation between the planned and actual position for all implants was 0.67 mm at the coronal level (entry point), 0.9 mm at the apical level, and 0.55 mm in depth, with an angle discrepancy of 2.50 degrees. Tracing 5 to 6 teeth tended to improve accuracy results compared to tracing 3 to 4 teeth. TR is as accurate as traditional registration and statically guided methods for implant surgery.
机译:已经引入了一种称为微量注册(TR)的技术,以允许植入物放置的动态导航,而无需热塑性支架。本研究进行了验证动态引导植入手术的TR协议的准确性。通过TR协议使用动态导航进行VIVO研究中的回顾性,观测到的。术前锥形光束计算机断层扫描(CBCT)计划叠加并通过术后CBCT扫描叠加并注册(对齐)以评估精度参数。总共136个植入物被置于59个部分透明的拱门中。所有植入物的计划和实际位置之间的平均偏差在冠状水平(入口点)处为0.67mm,在顶点水平下0.9mm,深度为0.55mm,角度差异为2.50度。与追踪3至4齿相比,追踪5至6齿倾向于提高精度结果。 TR与传统注册和静脉植入手术的静态指导方法一样准确。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号