首页> 外文期刊>The International journal of oral & maxillofacial implants >Retrospective and Clinical Evaluation of Aftermarket CAD/CAM Titanium Abutments Supporting Posterior Splinted Prostheses and Single Crowns
【24h】

Retrospective and Clinical Evaluation of Aftermarket CAD/CAM Titanium Abutments Supporting Posterior Splinted Prostheses and Single Crowns

机译:售后市场CAD / CAM钛基台的回顾性和临床评价支持后裂纹假体和单冠

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To evaluate the clinical outcomes of aftermarket computer-aided design/computer-assisted manufacturing (CAD/CAM) titanium abutments supporting splinted prostheses and single crowns in the posterior region. Materials and Methods: This study retrospectively evaluated the records of patients who received posterior implant-supported splinted restorations and single crowns supported by aftermarket CAD/CAM titanium abutments. Recall and clinical examination of the patients were performed between January 2017 and February 2018. A logistic regression was conducted to evaluate the influence of variables on the occurrence of complications and success rates. Correlations between the bone-level change and variables were calculated using the Spearman correlation. Results: One hundred thirty-five patients with 287 implants (86 crowns and 97 splinted prostheses) were recalled and examined clinically and radiographically after a mean observation period of 6.3 +/- 1.2 years (range 4.1 to 9 years). Failure of three implants led to a survival rate of 99.0%. Complications included 18 (9.8%) ceramic chippings, 15 (8.2%) screw loosenings, 8 (4.4%) decementations, 52 (38.5%) patients with peri-implant mucositis, and 9 (6.7%) patients with peri-implantitis. A significantly higher incidence of ceramic chipping occurred with bruxers (odds ratio [OR] = 3.939, 95% confidence interval [CI] = 1.28 to 12.09, P < .05). All screw loosenings occurred in single crowns. All decementations were observed in restorations cemented with temporary cement. Marginal bone loss around implants was significantly correlated with smoking (r = -0.155, P < .05). Hypertension was significantly associated with peri-implant mucositis (OR = 4.7, 95% CI = 1.65 to 13.39, P < .05). The technical success rate was 80.1%. The biologic success rate was 57%. There was no association between the restoration type and the success rates of the restorations. Conclusion: Using aftermarket CAD/CAM titanium abutments to support posterior restorations yielded comparable survival and success rates after a mean observation period of 6 years. However, in light of the relatively high incidence of screw loosenings, especially in patients receiving single-implant crowns, informing patients of the additional chairside aftercare with this type of treatment option is recommended.
机译:目的:评估售后市场电脑辅助设计/计算机辅助制造(CAD / CAM)钛支撑的临床结果,支撑夹板假体和后部区域中的单冠。材料和方法:本研究回顾性地评估了接收后部植入物支撑的夹持修复的患者的记录和售后市场CAD / CAM钛基台支撑的单个冠。召回患者的召回和临床检查是在2017年1月和2018年2月之间进行的。进行了逻辑回归,以评估变量对并发症和成功率发生的影响。使用Spearman相关计算骨级变化与变量之间的相关性。结果:一百三十五名患有287例植入物(86冠和97个夹层的假体)召回,并在临床上进行临床和放射线检查,在平均观察期为6.3 +/- 1.2岁(范围4.1至9年)。三个植入物的失败导致生存率为99.0%。并发症包括18(9.8%)陶瓷碎屑,15(8.2%)螺杆松动,8(4.4%)衰减,52例(38.5%)患有Peri-incomant Mositis的患者,9名(6.7%)患者患有肝炎患者。刷苷发生明显较高的陶瓷碎裂的发生率(差距[或] = 3.939,95%置信区间[CI] = 1.28至12.09,P <.05)。所有螺杆松动发生在单冠中。用临时水泥粘合的修复体内均观察到所有数量。植入物周围的边缘骨质损失与吸烟显着相关(R = -0.155,P <.05)。高血压显着与Peri-植入粘膜肌炎(或= 4.7,95%CI = 1.65至13.39,P <.05)显着相关。技术成功率为80.1%。生物成功率为57%。恢复类型与修复后的成功率之间没有关联。结论:采用售后市场CAD / CAM钛基台支撑后修复后,平均观察期为6年后得到了可比的存活率和成功率。然而,鉴于螺杆松动的相对较高的发病率,特别是在接受单植入冠的患者中,建议使用这种类型的治疗选择向患者提供额外的董事赛后。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号