首页> 外文期刊>AJNR. American journal of neuroradiology >Differences between internal jugular vein and vertebral vein flow examined in real time with the use of multigate ultrasound color doppler
【24h】

Differences between internal jugular vein and vertebral vein flow examined in real time with the use of multigate ultrasound color doppler

机译:使用多门超声彩色多普勒实时检查颈内静脉和椎静脉流量之间的差异

获取原文
获取原文并翻译 | 示例
       

摘要

BACKGROUND AND PURPOSE: The hypothesis that MS could be provoked by a derangement of the blood outflow from the brain has been largely discredited. In part, it was because data on the normal pattern of outflow are scarce and obtained with different methods. The aim of this study was to evaluate the normal pattern of outflow for the vertebral and internal jugular veins in healthy subjects with multigate color Doppler. MATERIALS AND METHODS: Twenty-five volunteers were studied to assess vessel area, mean velocity, and flow for the vertebral and internal jugular veins in the supine and sitting positions. RESULTS: In the sitting position, flow decreases, both in vertebral veins and internal jugular veins, as the total vessel area decreases (from 0.46 ± 0.57 to 0.09 ± 0.08 cm2), even if the mean velocity increases (from 12.58 ± 10.19 to 24.14 ± 17.60 cm/s). Contrary to what happens to the blood inflow, outflow in the supine position, through vertebral and internal jugular veins, is more than twice the outflow in the sitting position (739.80 ± 326.32 versus 278.24 ± 207.94 mL/min). In the sitting position, on application of very low pressure to the skin with the sonography probe, internal jugular veins rarely appear to occlude. A pronounced difference of diameter between internal jugular veins was present in approximately one-third of subjects. CONCLUSIONS: Our results support the view that other outflow pathways, like the vertebral plexus, play a major role in the normal physiology of brain circulation and must be assessed to obtain a complete picture of blood outflow.
机译:背景与目的:假说MS可能因大脑血液流出紊乱而引起。在某种程度上,这是因为关于正常流出模式的数据很少,并且是通过不同方法获得的。这项研究的目的是评估多门彩色多普勒健康受试者椎骨和颈内静脉的正常流出模式。材料与方法:研究了25名志愿者,以评估仰卧位和坐位的椎骨和颈内静脉的血管面积,平均速度和流量。结果:即使平均速度增加(从12.58±10.19到24.14),在坐位时,随着总血管面积的减少(从0.46±0.57到0.09±0.08 cm2),椎静脉和颈内静脉的流量都会减少。 ±17.60厘米/秒)。与血液流入相反,通过椎骨和颈内静脉的仰卧位流出量是坐位流出量的两倍多(739.80±326.32 vs 278.24±207.94 mL / min)。在坐姿中,当使用超声探头向皮肤施加极低的压力时,颈内静脉很少会闭塞。大约三分之一的受试者存在颈内静脉之间直径的明显差异。结论:我们的结果支持这样的观点,即其他流出途径,例如椎神经丛,在脑循环的正常生理中起主要作用,必须对其进行评估以获得完整的血液流出图。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号