...
首页> 外文期刊>Valve World >Effective SIS solutions: How Emergency Shutdown and HIPPS within SIS can meet IEC and ISA International Standards
【24h】

Effective SIS solutions: How Emergency Shutdown and HIPPS within SIS can meet IEC and ISA International Standards

机译:有效的SIS解决方案:SIS中的紧急停机和HIPP如何符合IEC和ISA国际标准

获取原文
获取原文并翻译 | 示例
           

摘要

Safety Instrumented Systems (SIS) play a critical role for industrial plants of all types throughout the world in that they prevent or reduce hazardous events by taking the process within that plant to a safe state when predetermined conditions are violated. A SIS typically includes the design and implementation of a variety of shutdown and/or blowdown valves. The three key components of a SIS are: 1) sensors or initiators that detect process conditions; 2) a logic solver that processes an input from the sensors to an output to the final elements; and 3) final elements that perform corrective actions by bringing the process to a safe state. An Emergency Shutdown Valve (ESDV) is the SIS Final Control Element. The Valve/Actuation Package is the weakest link in the Safety Instrumented Function (SIF), contributing greater than 50 percent of total Probability of Failure on Demand (PFD) for an SIF. The reliability, safety, and design of the final element has a significant impact on the overall Risk Reduction Factor. See Figure 1. Upgrading the SIS with a special focus on the Emergency Shutdown and High Integrity Pressure Protection subsystems can significantly improve both plant safety and reduce false trips. Emergency Shutdown Systems (ESD) and High Integrity Pressure Protection Systems (HIPPS) are two of several critical subsystems of a SIS - some others being Gas Systems (FGS), Instrumented Protective Systems (IPS), and Burner Management Systems (BMS).
机译:安全仪表系统(SIS)在全世界的所有类型的工业厂发挥着关键作用,因为当违反预定条件时,它们通过将该工厂的过程预防或减少危险事件。 SIS通常包括各种关断和/或排污阀的设计和实现。 SIS的三个关键组成部分是:1)检测过程条件的传感器或启动器; 2)将从传感器的输入处理到最终元素的输出的逻辑求解器; 3)通过将过程带到安全状态来执行纠正措施的最终元素。紧急关闭阀(ESDV)是SIS最终控制元件。阀门/致动封装是安全仪表功能(SIF)中最薄弱的链接,占SIF的需求(PFD)的概率大于50%。最终元素的可靠性,安全性和设计对整体风险减少因素产生了重大影响。请参见图1.升级SIS在紧急关闭和高完整性压力保护子系统中升级SIS,可以显着提高工厂安全性,减少虚假旅行。紧急关闭系统(ESD)和高完整性压力保护系统(HIPPS)是SIS的几个关键子系统中的两个 - 其他一些是天然气系统(FGS),仪器保护系统(IPS)和燃烧器管理系统(BMS)。

著录项

  • 来源
    《Valve World》 |2017年第3期|共3页
  • 作者

    Shawn Statham;

  • 作者单位

    Pentair Valves &

    Controls;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 TH134.1;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号