Recently, the use of magnetic dental implants has been re-popularized with the introduction of strong rare earth metal, for example, neodymium, magnets. Unrecognized magnetic dental implants can cause critical magnetic resonance image distortions. We report a case involving surgical failure caused by a magnetic dental implant. A 62-year-old man underwent deep brain stimulation for medically insufficiently controlled Parkinson's disease. Stereotactic magnetic resonance imaging performed for the first deep brain stimulation showed that the overdenture was removed. However, a dental implant remained and contained a neodymium magnet, which was unrecognized at the time of imaging; the magnet caused localized non-linear distortions that were the largest around the dental magnets. In the magnetic field, the subthalamic area was distorted by a 4.6 mm right shift and counter clockwise rotation. However, distortions were visually subtle in the operation field and small for distant stereotactic markers, with approximately 1-2 mm distortions. The surgeon considered the distortion to be normal asymmetry or variation. Stereotactic marker distortion was calculated to be in the acceptable range in the surgical planning software. Targeting errors, approximately 5 mm on the right side and 2 mm on the left side, occurred postoperatively. Both leads were revised after the removal of dental magnets. Dental magnets may cause surgical failures and should be checked and removed before stereotactic surgery. Our findings should be considered when reviewing surgical precautions and making distortion-detection algorithm improvements.
机译:最近,通过引入强稀土金属,例如钕,磁铁,已经重新推广使用磁性牙科植入物。无法识别的磁牙科植入物可能导致关键的磁共振图像失真。我们报告了涉及由磁性牙科植入物引起的手术失败的案例。一名62岁的男子接受了深入脑刺激,针对医学上不充分控制的帕金森病。对第一个深脑刺激进行的立体定向磁共振成像表明,除去过损。然而,牙科植入物保持并包含钕磁铁,在成像时未被识别;磁铁导致牙齿磁体周围最大的局部非线性扭曲。在磁场中,分离区域由4.6mm右移和逆时针旋转扭曲。然而,在操作场中的扭曲在视觉上微妙,对于远处立体定向标记的小,畸变大约1-2毫米。外科医生认为失真是正常的不对称性或变化。计算立体定向标记畸变是在手术计划软件中可接受的范围内的。术后,右侧约5毫米,左侧靶向误差,左侧2毫米。在去除牙齿磁铁后,这两个引线都被修改。牙科磁铁可能会导致手术故障,并在立体定向手术前检查和除去。在审查外科预防措施并进行失真检测算法改进时,应考虑我们的调查结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号