The aim of this ex vivo study was to test a novel three-dimensional (3D) automated computer -aided design (CAD) method (aCAD) for the computation of femoral angles in dogs from 3D reconstructions of computed tomography (CT) images. The repeatability and reproducibility of three manual radiography, manual CT reconstructions and the aCAD method for the measurement of three femoral angles were evaluated: (1) anatomical lateral distal femoral angle (aLDFA); (2) femoral neck angle (FNA); and (3) femoral torsion angle (FTA). Femoral angles of 22 femurs obtained from 16 cadavers were measured by three blinded observers. Measurements were repeated three times by each observer for each diagnostic technique. Femoral angle measurements were analysed using a mixed effects linear model for repeated measures to determine the levels of intra-observer agreement (repeatability) and inter-observer agreement (reproducibility). Repeatability and reproducibility of measurements using the aCAD method were excellent (intra-class coefficients, ICCs &= 0.98) for all three angles assessed. Manual radiography and CT exhibited excellent agreement for the aLDFA measurement (ICCs &= 0.90). However, FNA repeatability and reproducibility were poor (ICCs & 0.8), whereas FTA measurement showed slightly higher ICCs values, except for the radiographic reproducibility, which was poor (ICCs & 0.8). The computation of the 3D aCAD method provided the highest repeatability and reproducibility among the tested methodologies. (C) 2017 Elsevier Ltd. All rights reserved.
机译:该exvivo研究的目的是测试一种新颖的三维(3D)自动化计算机 - 提出的设计(CAD)方法(ACAD),用于从计算机断层扫描(CT)图像的3D重建的狗的股骨角度计算。评估了三个手动射线照相,手动CT重建和用于测量三个股骨角度的ACAT方法的可重复性和再现性:(1)解剖横向远端股角度(ALDFA); (2)股骨颈角(FNA); (3)股骨扭转角度(FTA)。由16个尸体从16个尸体获得的22个股骨的股骨角度由三个盲盲观察者测量。每个观察者对每个诊断技术的观察者重复测量三次。使用混合效应线性模型进行分析股骨角度测量,以确定反复措施,以确定观察者内部协议(可重复性)和观察者间协议(可重复性)的水平。使用ACAD方法的测量的可重复性和再现性是优异的(类级系数,ICCS& = 0.98),用于所有三个角度评估。手动射线照相和CT对AldFA测量表现出很好的协议(ICCS& = 0.90)。然而,FNA可重复性和再现性差(ICCS& LT; 0.8),而FTA测量显示出略高的ICCS值,除了较差的射线照相再现性(ICCS& 0.8)。 3D ACAD方法的计算提供了测试方法中的最高可重复性和再现性。 (c)2017 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号