首页> 外文期刊>The Knee >Is arthroscopic videotape a reliable tool for describing early joint tissue pathology of the knee?
【24h】

Is arthroscopic videotape a reliable tool for describing early joint tissue pathology of the knee?

机译:关节镜录像带是一种可靠的工具,用于描述膝盖的早期关节组织病理学?

获取原文
获取原文并翻译 | 示例

摘要

Abstract Background The aim of this study was to assess the reliability of the videotape scoring system collected during knee arthroscopy for meniscal tears, and to test the consistency with intra-operative findings. Methods Fifty-seven patients undergoing arthroscopic treatment of meniscal tears were included in the analysis. The cartilage damage was assessed intra-operatively, at six sites, using the Outerbridge scoring system. The meniscal tears were graded according to the International Society of Arthroscopy, Knee Surgery and Orthopaedic Sports Medicine (ISAKOS) classification. The presence of synovial inflammation was scored, at four different sites, according to the macro-score method. The total cartilage, meniscal and synovial scores were calculated for each knee by the sum of the maximum grade of the lesions at each anatomic site. In order to assess the reliability of the arthroscopic scoring system, the videotapes recorded during the arthroscopy were reviewed by two independent observers one year after the surgery and compared with the scores completed by the surgeon during the operation. Results The total cartilage score showed substantial inter-rater and intra-rater reliability, and moderate consistency with the intra-operative score provided by the surgeon. The total meniscal score showed substantial inter-rater and intra-rater reliability, and good consistency with the intra-operative findings. The total synovial score showed substantial inter-rater agreement, substantial intra-rater reliability, and moderate consistency with intra-operative findings. Conclusions The videotape scoring system provided a reliable and reproducible system for recording the intra-operative state of the whole joint pathology in patients undergoing arthroscopic treatment of meniscal tears.
机译:摘要背景本研究的目的是评估录像带在膝关节视镜检查期间收集的录像带评分系统的可靠性,并测试与操作内发现的一致性。方法分析中包括五十七名接受关节镜下治疗半月岩的患者。使用外桥评分系统,在六个地点进行术语可操作地评估软骨损坏。 Mendiscal泪水根据国际关节镜,膝关节手术和骨科体育医学(ISAKOS)分类进行评分。根据宏观评分法,在四个不同的位点评分滑膜炎症的存在。每个膝关节计算总软骨,半月板和滑膜分数,每膝的每个解剖部位的病变的最大等级的总和。为了评估关节镜评分系统的可靠性,在手术后一年通过两个独立观察员记录在关节镜检查期间的录像带,并与外科医生在运营期间完成的分数相比。结果总软骨分数显示出实质性的帧间间和帧内可靠性,以及外科医生提供的术语分数的中等一致性。半月板分数显示出实质性的帧间间和帧内可靠性,以及术中的术语表现出良好的一致性。总滑膜分数显示出实质性的帧间间协议,大量的帧内可靠性和与术室内的调查结果中度一致。结论录像带评分系统提供了一种可靠和可重复的系统,用于记录接受半透镜撕裂关节镜治疗的患者的整个关节病理学的手术内的术语。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号