首页> 外文期刊>The journal of sexual medicine >Penile Size Restoration With Nondegloving Approach for Peyronie’s Disease: Initial Experience
【24h】

Penile Size Restoration With Nondegloving Approach for Peyronie’s Disease: Initial Experience

机译:对Peyronie疾病的非抛光方法的阴茎尺寸恢复:初始经验

获取原文
获取原文并翻译 | 示例
           

摘要

IntroductionThe sliding technique (ST), commonly done with a subcoronal circumcising incision with penile degloving, has been used to restore penile size in patients with severe Peyronie’s disease (PD) and erectile dysfunction, but with a potential risk of ischemic injury to the glans penis. AimTo provide detailed surgical techniques regarding the nondegloving ventral incision and report our initial experience with this approach to perform the ST and penile prosthesis placement in patients with severe PD. MethodsThis was a retrospective review of patient outcomes after penile prosthesis placement with penoplasty for severe PD and erectile dysfunction from January 2015 to December?2017. Main Outcome MeasuresPrimary outcomes included straightening rates, penile measurement, along with immediate and late complications. Secondary outcomes include operative time and overall patient satisfaction. Results12 Patients had significant penile atrophy and/or curvature >60 degrees and underwent inflatable penile prosthesis placement with grafting procedure. Significant penile atrophy was determined by a combination of the patient’s subjective report and the surgeon’s objective assessment through stretched penile length. 7 (58.3%) of those patients underwent ST, of which the last 5 had the procedure performed through a nondegloving ventral incision. Mean degree of curvature prior to ST was 66 degrees (45–90 degrees). Mean penile length gain was 2.6 cm (2.0–3.0 cm). At a mean follow-up of 15.5 months (3–31 months), only 1 patient had minimal residual curvature of 15 degrees. There were no vascular complications. Clinical ImplicationsThis nondegloving technique theoretically maintains blood flow continuity to the glans penis by preserving the continuity of the skin, dartos fascia, and neurovascular bundle. Strengths & LimitationsStrengths of this study include the novel nature of this approach, no incidence of vascular complications, and adaptability to other grafting procedures during penile prosthesis placement. Limitations include the use of 5-item International Index of Erectile Function scores to assess preoperative erectile function on PD, small population, longer incision, and a possible steep learning curve. ConclusionWhile ischemic complications of ST and penile prosthesis implantation are rare, there are reports of ischemic injury in patients undergoing a subcoronal circumcising incision with penile degloving. The non-degloving technique with ventral incision provides for an alternative method for ST and penile prosthesis placement to maintain dartos and skin continuity to the glans penis while still allowing for adequate surgical exposure.Clavell-Hernández J, Wang R. Penile Size Restoration With Nondegloving Approach for Peyronie’s Disease: Initial Experience. J Sex Med 2018;15:1506–1513.
机译:介绍滑动技术(ST),通常用具有阴茎脱模的次要肩部切口,已用于恢复严重的PEYRONIE疾病(PD)和勃起功能障碍的患者中的阴茎大小,但对龟头阴茎造成缺血性损伤的潜在风险。 AIMTO提供关于Nondegloving腹部切口的详细手术技巧,并通过这种方法报告我们的初始经验,以对严重PD的患者进行ST和阴茎假体放置。方法是,2015年1月至12月的严重PD和勃起功能障碍的阴部术后,对患者结果进行了回顾性审查患者结果。2017年12月主要结果是衡量结果包括矫直率,阴茎测量以及即时和后期并发症。二次结果包括手术时间和总体患者满意度。结果12患者具有显着的阴茎萎缩和/或曲率> 60度,并随着接枝程序进行可充气阴茎假体放置。通过患者主观报告和外科医生通过拉伸阴茎长度的目标评估来确定显着的阴茎萎缩。 7(58.3%)的患者接受过ST的患者,其中最后5次通过Nondegloving腹部切口进行的程序。 ST之前的平均曲率是66度(45-90度)。平均阴茎长度增益为2.6厘米(2.0-3.0cm)。在15.5个月(3-31个月)的平均随访中,只有1例患者的剩余曲率为15度。没有血管并发症。通过保留皮肤,Dartos筋膜和神经血管束的连续性理论上,Nondegloving技术理论上将血液流动连续性保持在龟头阴茎。本研究的优势和局限性包括这种方法的新颖性,没有血管并发症的发生率,以及在阴茎假体放置期间对其他移植程序的适应性。限制包括使用5项国际勃起函数分数指标,以评估PD,小人口,更长的切口和可能的陡峭学习曲线上的术前勃起功能。结论缺血性并发症ST和阴茎假体植入罕见,有缺血性损伤的报道,患者患有阴茎脱落的次要胁迫下切口。具有腹部切口的非脱模技术提供了ST和阴茎假体放置的替代方法,以维持龟头阴茎的Dartos和皮肤连续性,同时仍然允许适当的外科暴露。Clavell-HernándezJ,王R.与Nondegloving的阴茎尺寸恢复PEYRONIE疾病的方法:初步体验。 J SEX MED 2018; 15:1506-1513。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号