Objective: To assess the plausibility of using the continuous glucose monitoring as a sole source of data for the screening of the neonatal hypoglycemia. Study design: Infants of mothers with diabetes were screened for neonatal hypoglycemia (less than 2.5 mmol/l after 4 h of life). Initial measurement was performed using point of care analyzer. We applied continuous glucose monitoring system subsequently. Infants were monitored up to 5 days or until discharge. Results: Out of 32 infants 11 had postnatal hypoglycemia resolved within 12 h of life. Two infants had hypoglycemia found due to continuous glucose monitoring after 24 h of life when sufficient feeding was established and they did not show any signs of hypoglycemia. We did not have any false negative measurements. No infant showed clinical signs of neonatal hypoglycemia. Conclusions: Continuous glucose monitoring is plausible and safe to use for screening of neonatal hypoglycemia. It operates well within the range that is accepted as safe for neurodevelopment. In addition, it can be used after first day of life where regular screening ends. Limitation of this method is possible alarm negligence of caregivers.
机译:目的:评估使用连续葡萄糖监测作为筛选新生儿低血糖症的唯一数据来源的合理性。研究设计:患有糖尿病患者的婴儿被筛查新生儿低血糖(4小时后小于2.5mmol / L)。使用护理点分析仪进行初始测量。我们随后应用连续血糖监测系统。监测婴儿长达5天或直至放电。结果:32名婴儿11中的产后低血糖在生命的12小时内得到了解决。由于建立了足够的喂养后24小时后,两名婴儿发现了由于连续葡萄糖监测而发现,并且它们没有显示出任何低血糖症的任何迹象。我们没有任何假阴性测量。没有婴儿显示新生儿低血糖的临床迹象。结论:用于筛查新生儿低血基血症,连续葡萄糖监测是可粘性和安全的。它在接受为神经发作的安全范围内运行。此外,它可以在定期筛选结束的生命的第一天后使用。这种方法的限制是可能的警报疏忽的护理人员。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号