首页> 外文期刊>The Journal of arthroplasty >Trabecular Metal Acetabular Components Reduce the Risk of Revision Following Primary Total Hip Arthroplasty: A Propensity Score Matched Study From the National Joint Registry for England and Wales
【24h】

Trabecular Metal Acetabular Components Reduce the Risk of Revision Following Primary Total Hip Arthroplasty: A Propensity Score Matched Study From the National Joint Registry for England and Wales

机译:小梁金属髋臼组件降低了主要总髋关节置换术后修订的风险:英格兰和威尔士国家联合登记处的倾向评分匹配研究

获取原文
获取原文并翻译 | 示例
           

摘要

Abstract Background Trabecular metal (TM)-coated acetabular components are increasingly used in both primary and revision total hip arthroplasty (THA). However, previous studies assessing TM acetabular components have been small single-center cohorts with most lacking a control group. We compared revision rates following primary THA between TM and non-TM-coated acetabular components. Methods A retrospective observational study was performed using National Joint Registry data, which included primary THAs with the same cementless acetabular component (either TM or non-TM coated). TM and non-TM implants were matched for multiple potential confounding factors using propensity scores. Outcomes following primary THA (revision for all-cause acetabular indications, aseptic acetabular loosening, and infection) were compared between matched groups using competing risk regression analysis. Results In 18,200 primary THAs (9100 TM and 9100 non-TM), the overall prevalence of acetabular revision, revision for aseptic acetabular loosening, and septic revision was 1.2%, 0.13%, and 0.59% respectively. Five-year revision rates for all-causes (1.0% vs 1.8%, sub-hazard ratio [SHR] 0.57, 95% confidence interval [CI] 0.43-0.76, P P ?= .029), and infection (0.5% vs 0.9%, SHR 0.51, 95% CI 0.34-0.76, P ?= .001) were all lower in TM compared with non-TM implants. Conclusion Following primary THA, TM-coated acetabular implants had a reduced risk of both aseptic and septic revision compared with non-TM implants. Although absolute differences in revision risk were small, they may be clinically significant if TM designs were implanted in more complex cases.
机译:摘要背景鲜明金属(TM)涂覆的髋臼组分越来越多地用于初级和修订总髋关节置换术(THA)。然而,以前的研究评估了TM髋臼成分的小型单中心队列,最缺乏对照组。我们在TM和非TM涂覆的髋臼组件之间进行初级THA后比较修订率。方法采用国家联合注册表数据进行回顾性观察研究,其中包括具有相同粘土的髋臼组分(TM或非TM涂层)的主要THA。使用倾向分数与多个潜在的混淆因子匹配TM和非TM植入物。在匹配的基团之间使用竞争风险回归分析比较母素后的结果(对全导致髋臼适应症的修订,无菌髋臼松动和感染)。结果18,200名主要THA(9100 TM和9100非TM),髋臼修正的总体流行率,无菌髋臼松动的修正分别为1.2%,0.13%和0.59%。所有原因的五年修订率(1.0%vs 1.8%,子危害比[SHR] 0.57,95%置信区间[CI] 0.43-0.76,PP?= .029)和感染(0.5%VS 0.9与非TM植入物相比,%,4.51,95%CI 0.34-0.76,P?= .001)全部均低于TM。结论初级THA后,与非TM植入物相比,TM涂覆的髋臼植入物的风险降低了无菌和化粪池修正。虽然修改风险的绝对差异很小,但如果在更复杂的情况下植入TM设计,它们可能是临床意义。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号