首页> 外文期刊>The Journal of craniofacial surgery >Repeatability Study of Angular and Linear Measurements on Facial Morphology Analysis by Means of Stereophotogrammetry
【24h】

Repeatability Study of Angular and Linear Measurements on Facial Morphology Analysis by Means of Stereophotogrammetry

机译:通过立体术分析角度和线性测量的可重复性研究

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to analyze the repeatability in a stereophotogrammetry digital system used for the evaluation of facial morphology. Thirty healthy Brazilian, 18 to 45 years old (26.71 +/- 6.53), had 11 reference landmarks marked on their faces by the same examiner and were photographed with an interval of 1 week by the VECTRA M3. Nine angular measurements (nasolabial, mentolabial, nasofrontal, maxillofacial, nasal, maxillary, mandibular, facial convexity, full facial convexity) and 2 linear measurements (middle facial height and lower facial height) were taken. Repeatability was analyzed by the mean absolute differences, relative error of magnitude, technical error of measurement, intraclass correlation coefficient, and Bland-Altman analysis. Paired t test sought any systematic errors between the acquisitions. Associations among body mass index, age, and the error in the measurements were made using the Pearson correlation coefficient. For the technical error of measurement, the nasolabial and mentolabial angles showed values > 28 (clinical limit set for this study). For the relative error of measurement, most of the measures were rated between good and excellent. The maxillofacial angle was only moderate. There was a systematic error for middle facial height. The nasolabial, mentolabial, facial convexity, full facial convexity, maxillofacial, and nasofrontal angles presented intraclass correlation coefficient values rated as excellent. The relationship between age/body mass index and the error found between measurements was not confirmed. The nasolabial and mentolabial angles should be interpreted with caution due to the variability showed. The results found stereophotogrammetry to be repeatable, giving accurate measures within the references established for this study.
机译:本研究的目的是分析用于评估面部形态学的立体光学擦拭数字系统中的可重复性。三十个健康的巴西人,18至45岁(26.71 +/-6.53),同一审查员在他们的面前有11个参考地标,并被Vectra M3的一周间隔拍摄。采用九个角测量(鼻涕,胶质球,鼻向前,颌面,鼻腔,颌骨,颌骨,面部凸起,全面部凸起)和2个线性测量(中间面部高度和下部高度)。通过平均绝对差异,幅度相对误差,测量技术误差,跨越相关系数和Bland-Altman分析来分析重复性。配对T检验在收购之间寻求任何系统错误。使用Pearson相关系数进行体重指数,年龄和测量中的误差之间的关联。对于测量的技术误差,鼻涕和椎弓根角显示值> 28(本研究临床限制)。对于测量的相对误差,大部分措施都是良好且优秀的措施。颌面积仅适度。中面部高度有一个系统的错误。鼻涕,胶质肿,面部凸起,全面部凸,颌面和鼻散孔角度呈现出额定额定的相关系数值。未确认年龄/体重指数与测量之间发现的误差之间的关系。由于变异性显示,鼻根和蛋白质角度应谨慎地解释。结果发现立体相处理是可重复的,在为本研究建立的参考文献中提供准确的措施。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号