Low-cost mobile open-circuit hood system for measuring gas exchange in small ruminants: from manual to automatic recording

机译:低成本移动开路罩系统,用于测量小型反刍动物气体交换:从手动到自动录音

获取原文
获取原文并翻译 | 示例
           

摘要

Improvements of a home-made mobile open-circuit respirometry system for the rapid determination of methane (CH4) and carbon dioxide (CO2) production, oxygen (O-2) consumption and, thereafter, heat production (HP) for small ruminants are described and validated. Upgrades consisted of three main features: utilization of a head hood (replacing the previous face mask); use of a computerized control system, data acquisition and recording for gases and air flux (replacing collecting bags for air sampling); and use of a gas cooler to remove the air sample moisture (replacing the chemical drier (silica gel) approach). Calibration factors were established by injecting nitrogen (N-2) and CO2 in the system into the head hood. Repetitive and consistent values for the calibration factor were obtained for O-2 and CO2 which confirmed the absence of leaks and the good performance of the system. In addition, an experimental test with 12 Manchega female dry sheep was conducted to validate the system. Three diets based on cereal grain, fibrous by-products and alfalfa hay (ALH) were used with four sheep per diet. Metabolizable energy intake was close to metabolizable energy for maintenance. Average HP measured by indirect calorimetry (respiratory quotient (RQ) method) was close to the average HP determined from Carbon-Nitrogen balance (CN method) accounting for 443 and 426 kJ/kg(075) body weight (BW) per day, respectively. Fasting HP was determined by the RQ method with two sheep from the ALH diet accounting for 269 kJ/kg(075) BW per day. The head hood and computerized control, data acquisition and recording as well as the gas cooler improved the system by reducing the labour input without loss of functionality for measuring gas exchange and energy metabolism in small ruminants.
机译:描述了用于快速测定甲烷(CH4)和二氧化碳(CO2)生产,氧(O-2)消耗的自制移动开路呼吸系统系统的改进,此后,用于小反刍动物的热量生产(HP)并验证。升级包括三个主要特点:利用头部罩(更换前面膜);使用计算机化控制系统,数据采集和用于气体和空气通量的记录(更换用于空气采样的收集袋);使用气体冷却器以除去空气样品(更换化学干燥剂(硅胶)接近)。通过将系统中的氮(N-2)和CO 2注入头部罩来建立校准因子。为O-2和CO2获得校准因子的重复和一致的值,其证实没有泄漏和系统的良好性能。此外,对12个Manchega女性干羊进行了实验测试以验证系统。三种基于谷物籽粒,纤维副产品和苜蓿干草(ALH)的饮食用每次饮食四只绵羊使用。可代谢的能量摄入接近可达到的维护能量。通过间接量热法测量的平均HP(呼吸商(RQ)方法)接近碳 - 氮平衡(CN方法)测定的平均HP分别占每天443和426 kJ / kg(075)体重(BW) 。禁食HP由RQ方法确定,来自ALH饮食的两只绵羊占每天269 kJ / kg(075)BW。通过减少劳动力输入而不会损失测量小型反刍动物的气体交换和能量代谢,可以通过减少劳动力输入来改善系统的头部罩和计算机控制,数据采集和记录以及气体冷却器改进了系统。

著录项

  • 来源
  • 作者单位

    Univ Politecn Valencia Inst Anim Sci &

    Technol Valencia 46022 Spain;

    Univ Politecn Valencia Inst Anim Sci &

    Technol Valencia 46022 Spain;

    CSIC Estac Expt Zaidin Dept Physiol &

    Biochem Anim Nutr Granada 18100 Spain;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 农业科学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号