In this study, linseed oil-filled urea-formaldehyde-based microcapsules containing cerium acetate (Ce) and 8-Hydroxyquinoleine (8-HQ) were synthesized in an oil-in-water emulsion via in-situ polymerization method. The Field Emission Scanning Electron Microscopy (FE-SEM) and Optical Microscopy (OM) were used to study the shape and morphology of the prepared microcapsule. The results revealed the regular spherical capsules with 20-120 mu m diameters. Prepared microcapsules were dispersed in the epoxy matrix in single (Ce and 8-HQ) and mixed (50 wt.% Ce + 50 wt.% 8-HQ) forms. Electrochemical Impedance Spectroscopy (EIS) and standard salt spray test were conducted to study anti-corrosion properties of different epoxy-based samples on the mild steel substrate. The results revealed improved anti-corrosion and healing performance of microcapsule embedded coating samples compared with their blank counterparts during 28 days exposure to the salt spray test conditions. The sample containing mixed form microcapsules showed the best performance among all samples. After one-week immersion in 3.5 wt.% NaCl electrolyte, vertical bar Z vertical bar at low-frequency value (vertical bar Z vertical bar(lf)) for neat epoxy, 8-HQ, Ce and mixed forms samples decreased from 2.81 x 10(8), 2.70 x 10(9), 1.02 x 10(9) and 8.62 x 10(9) to 1.22 x 10(4), 2.69 x 10(8), 3.40 x 10(7) and 1.98 x 10(9) (ohm. cm(2)), respectively. Finally, fluorescence microscopic study showed that the 8-HQ compound was released at the damaged area on the coated substrate and detects the corrosion phenomenon at the early stage as a smart corrosion indicator.
机译:在本研究中,通过原位聚合方法在水包油乳液中合成含有醋酸铈(Ce)和8-羟基喹啉(8-HQ)的亚麻籽油填充脲醛微胶囊。场发射扫描电子显微镜(Fe-SEM)和光学显微镜(OM)用于研究制备的微胶囊的形状和形态。结果显示了具有20-120μm的正则球形胶囊。将制备的微胶囊分散在单一(Ce和8-HQ)中的环氧基质中,并混合(50重量%Ce + 50重量%8-HQ)形式。进行电化学阻抗光谱(EIS)和标准盐喷雾试验,以研究在低碳钢基材上的不同环氧基样品的抗腐蚀性能。结果表明,在28天暴露于盐雾试验条件下,与其坯料对应物相比,微胶囊嵌入涂层样品的抗腐蚀和愈合性能提高了微胶囊嵌入式涂层样品。含有混合形式微胶囊的样品显示所有样品中的最佳性能。在3.5重量%的3.5重量%中浸没。%NaCl电解质,用于纯环氧物的低频值(垂直条Z垂直条(LF))的垂直条Z垂直条,8-HQ,Ce和混合形式样品从2.81 x降低10(8),2.70×10(9),1.02×10(9)和8.62×10(9)至1.22 x 10(4),2.69 x 10(8),3.40 x 10(7)和1.98 x 10 (9)(欧姆.CM(2))。最后,荧光显微镜研究表明,8-HQ化合物在涂覆的基材上的受损区域处释放,并在早期阶段作为智能腐蚀指示器检测腐蚀现象。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号