Hip simulation is a common technique for pre-clinical evaluation of wear performance of total hip arthroplasty. Standard techniques replicate kinematics of walking patterns of a typical patient. Attention has focussed in developing simulations of other typical patient daily activities to improve accuracy of wear predictions. A method for simulating stop-dwell-start motion during patient walking and the effect on 36-mm metal-on-metal total hip arthroplasty was previously presented by the authors. This study sought to extend the previous work to look at the effect of these conditions on ceramic-on-ceramic, metal-on-polyethylene and ceramic-on-polyethylene bearings. Two stop-dwell-start protocols were used: one reproducing average patient movement patterns and one examining more severe conditions. For all materials tested, no significant increase in wear was observed under average stop-dwell-start conditions, suggesting the bearing types tested are robust to this type of activity. A significant increase in wear was observed for metal-on-metal, metal-on-polyethylene and ceramic-on-polyethylene bearings under severe stop-dwell-start conditions, this was attributed to depletion of lubricant in the bearing during the dwell period. A greater relative increase in wear was observed for metal-on-metal bearings compared with metal-on-polyethylene and ceramic-on-polyethylene bearings. This may be explained by the contributions of the different lubrication mechanisms in each bearing type. Wear of ceramic-on-ceramic was very low in all tests, suggesting normal measurement variation was masking any effect of the adverse conditions. It was not possible to determine any effect of the different activities. These results emphasise the importance of exploring adverse patient activity simulations. The increase in wear rate associated with an adverse activity such as seen in stop-dwell-start motion, has to be considered in the context of the frequency of the adverse activity cycle relativ
机译:HIP模拟是总髋关节置换术磨损性能的临床临床评价的常用技术。标准技术复制典型患者的行走模式的运动学。注意力侧重于开发其他典型患者日常活动的模拟,以提高磨损预测的准确性。在患者行走期间模拟停留停留 - 开始运动的方法,并由作者提出了对36毫米金属总髋关节置换术的影响。该研究试图延长以前的作品,以了解这些条件对陶瓷上的陶瓷,金属的聚乙烯和陶瓷 - on-聚乙烯轴承的影响。使用了两种停止停留 - 开始协议:一种再现平均患者运动模式,以及一个检查更严重的条件。对于所有测试的材料,在平均停留 - 停留条件下观察到磨损的显着增加,表明测试的轴承类型对这种活动具有鲁棒性。在严重的止动止血 - 启动条件下,观察到金属上金属,金属对聚乙烯和陶瓷对聚乙烯轴承的磨损显着增加,这归因于停留期间轴承中润滑剂的耗尽。与金属对金属轴承相比,观察到磨损的磨损更大的相对增加,与金属对聚乙烯和聚乙烯轴承相比。这可以通过各轴承类型中的不同润滑机构的贡献来解释。所有测试中,陶瓷上陶瓷的磨损非常低,表明正常的测量变化掩盖了不利条件的任何效果。无法确定不同活动的任何效果。这些结果强调探索不利患者活动模拟的重要性。与在止动止血 - 开始运动中看到的不利活动相关的磨损率的增加必须在不利活动周期的频率的上下文中考虑在不利活动周期的频率的上下文中

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号