The effect of dental implant parameters, length and diameter, and thread parameters consisting of thread depth, width, pitch and inner angle on Max von-Mises stress in implant-abutment and cancellous bone is investigated. A three-dimensional finite element model of a threaded dental implant and mandibular segment is built. Face-centered central composite design is applied as the design of experiments method to study and optimize the six independent variable parameters at three levels by applying response surface methodology. The simultaneous analysis of these parameters is run to obtain a better perspective on their effects on responses. The effects of linear, square, and interactive terms on responses through Pareto, main effects, and interaction plots are determined through analysis of variance. A second-order polynomial equation is fitted to the model to predict the response magnitude. The results indicate that implant diameter and its interaction with thread depth are effective in decreasing the likelihood of bone resorption. The implant length affects the Max von-Mises stress in implant-abutment, with no effect on the Max von-Mises stress in cancellous bone. The optimization process caused about 10% and 30% reduction in the magnitude of Max von-Mises stress in implant-abutment and cancellous bone, respectively.
机译:研究了牙科植入物参数,长度和直径,以及螺纹深度,宽度,沥青和内角度的螺纹参数,在植入基础上的最大vonmmes应激上构成的螺纹深度和内角。建立了螺纹牙科植入物和下颌段的三维有限元模型。居中的中央复合设计应用于实验方法的设计,通过施加响应表面方法,在三个级别研究和优化六个独立变量参数。运行对这些参数的同时分析,以获得对它们对响应的影响更好的视角。通过差异分析确定线性,方形和交互术语对通过帕累托,主要效应和相互作用图的反应的影响。二阶多项式方程安装在模型中以预测响应幅度。结果表明,植入直径及其与螺纹深度的相互作用在降低骨吸收的可能性方面是有效的。植入长度影响植入静脉中的最大vonmmes应激,对松质骨中的最大von-mises应激没有影响。优化过程分别引起植入物 - 邻接和松质骨中最大vonmmms应激幅度的10%和30%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号