首页> 外文期刊>Power engineer journal >CONSIDERATION OF FAULT CURRENT PROJECTION ON ACCOUNT OF FUTURE GROWTH FOR EARTHING DESIGN - SHARING AN EXPERIENCE
【24h】

CONSIDERATION OF FAULT CURRENT PROJECTION ON ACCOUNT OF FUTURE GROWTH FOR EARTHING DESIGN - SHARING AN EXPERIENCE

机译:考虑到接地设计未来增长的故障电流投影 - 分享体验

获取原文
获取原文并翻译 | 示例
       

摘要

Design of earthing system of AC substation is largely depend upon the Grid current. The grid current Ig is derived from formula given in IEEE -80 where fault circuit current is multiplied with two other factors Df (decrement factor due to DC component of AC waveform) and Sf (current division factor). Decrement factor and Current Division factor can be considered from well established formulae and table in IEEE 80. Further the increase in fault level due to future development in the power system is really most critical issue and shall be considered with due care to take the final grid current. It is humble effort to provoke the thoughts on the issue at large level amongst various utilities so that some reference value can be judged while designing the earthing grid. Even though it is purely customized value for particular system where the design is going to be adopted, sharing experience of various utilities may help the design fraternity in assuming the correct factor. This paper describes practical trend of increase in fault level of a substation based on the author's experience and database collected. IEEE 80-2013 suggests that due care should be taken in consideration of increase in fault current as future development will reduce the current division factor as some new lines and/or neutrals will come into circuit and hence it may compensate the increase in current thus any more factor if considered for increase in current will cause the over design the grid. Example is quoted in the paper to illustrate the effect of increase in fault current with the decrease in division factor.
机译:AC变电站的接地系统的设计主要取决于网格电流。网格电流Ig衍生自IEEE -80中给出的公式,其中故障电路电流乘以另外两个因素DF(由于AC波形的DC分量而导致的衰减系数)和SF(电流分割因子)。可以从IEEE 80中成熟的公式和表中考虑减量因子和电流分裂因子。进一步增加由于电力系统中未来发展导致的故障水平的增加确实是最关键的问题,并应考虑采取措施采取最终网格当前的。在各种公用事业公司中,在大级别挑起了对问题的思考是谦逊的努力,以便在设计接地网格时可以判断一些参考价值。尽管它是特定系统的纯粹定制价值,但是将采用设计的特定系统,但各种公用事业公司的共享体验可能有助于假设正确因素的设计兄弟会。本文介绍了基于作者的经验和收集的数据库的变电站故障水平增加的实际趋势。 IEEE 80-2013表明,应考虑到由于未来的发展将减少当前的划分因素,因为一些新的线条和/或中性将进入电路,因此可能会补偿任何如果考虑增加电流会导致电网的增加,则更多因素会导致网格。引用示例以说明随着分割因子的降低,故障电流增加的效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号