...
首页> 外文期刊>Pharmacoepidemiology and drug safety >Positive predictive value of ICD-10 codes to detect anaphylaxis due to vaccination: A validation study
【24h】

Positive predictive value of ICD-10 codes to detect anaphylaxis due to vaccination: A validation study

机译:ICD-10代码的阳性预测值以疫苗接种导致检测过敏性:验证研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Purpose To validate the use of selected International Classification of Disease Codes 10th revision (ICD-10) to predict (positive predictive value) anaphylaxis due to vaccination using emergency department (ED) data. Methods We conducted a retrospective study using ED encounter data from a large tertiary-care teaching hospital, Monash Medical Centre, Melbourne, Australia. We searched all ED encounters potentially due to anaphylaxis after vaccination, between 1 January 2010 and 31 December 2018, using ICD-10-CM codes T80.5, T80.6, T88.1, T88.6, and T78.2. Health records of potential cases were examined to determine if they met the Brighton Collaboration (BC) criteria for anaphylaxis. We calculated the PPV to evaluate the accuracy of the selected ICD-10-CM codes in predicting anaphylaxis due to vaccination. Results Of the 69 health records identified and reviewed, 29 (42.2%) met the criteria for anaphylaxis regardless of the cause, and 24.6% (17/69) of records were confirmed as anaphylaxis triggered by vaccination (low positive predictive value). However, of the 23 records identified using ICD-10-CM code T80.5, 22 were classified as anaphylaxis cases regardless of the cause, and 12 were anaphylaxis due to vaccination cases giving PPV of 95.7% and 52.2%, respectively. Conclusions Given that there is no specific ICD-10-CM code for anaphylaxis due to vaccination, ICD-10-CM code T80.5 may be suitable to monitor anaphylaxis due to vaccination in the ED setting. The current study was conducted at a single centre and needs to be confirmed by future multicentre studies.
机译:目的为了验证使用所选择的疾病代码第10次修订(ICD-10)的使用,以预测(阳性预测值)由于使用急诊部(ED)数据的疫苗接种而导致的过敏反应。方法采用来自澳大利亚墨尔本墨尔本蒙纳什医疗中心的Ed Encount数据进行了回顾性研究。我们在2010年1月1日至2018年12月31日之间疫苗接种后,我们在疫苗接种后潜在地搜查了所有ed遭遇,使用ICD-10-CM代码T80.5,T80.6,T88.1,T88.6和T78.2。审查了潜在案件的健康记录,以确定他们是否符合过敏反应的布赖顿协作(BC)标准。我们计算了PPV,以评估所选择的ICD-10-CM代码的准确性预测由于疫苗接种而预测过敏性。确定和审查和审查的69条健康记录的结果达到了过敏反应的标准,无论原因如何,24.6%(17/69)记录被证实为通过疫苗接种引发的过敏反应(低阳性预测值)。然而,在使用ICD-10-CM代码T80.5,22鉴定的23条记录中被分类为过敏反应病因,无论原因如何,由于疫苗接种案例分别为PPV为95.7%和52.2%的疫苗接种症。结论给出由于疫苗接种导致的过敏反应的特定ICD-10-CM代码,ICD-10-CM代码T80.5可以适合于监测由于ED设置中的疫苗接种而监测过敏反应。目前的研究是在单一中心进行的,需要通过未来的多元研究证实。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号