首页> 外文期刊>Sleep & breathing =: Schlaf & Atmung >Validity analysis of respiratory events of polysomnography using a plethysmography chest and abdominal belt
【24h】

Validity analysis of respiratory events of polysomnography using a plethysmography chest and abdominal belt

机译:用体积描记胸和腹带的多膜凝视呼吸事件的有效性分析

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose Respiratory inductive plethysmography (RIP) is recommended as an alternative respiratory sensor for the identification of each apnea and hypopnea event in polysomnography. Using this sensor, the cumulative RIP results from the chest and abdomen (RIP sum) and time-derived results of the RIP sum (RIP flow) are calculated to track respiratory flow. However, the effectiveness of this sensor and the calculated respiratory results is still unclear, and validation studies for the scoring of respiratory events in polysomnography are rare. Methods Two hundred subjects were selected according to the severity of obstructive sleep apnea. A sleep specialist re-evaluated the respiratory events based on RIP flow data in a single-blind study. Statistical analysis was conducted with paired respiratory events scored in each of the RIP flow and polysomnography datasets. Results All respiratory events scored from the RIP flow were strongly correlated with those identified with standard sensors of polysomnography, regardless of disease severity. Most of the respiratory parameters from RIP flow trended toward underestimation. The RIP flow obtained from the alternative RIP sensor was appropriate for the diagnosis of obstructive sleep apnea based on a receiver operating characteristic curve. Conclusions Scored respiratory events from RIP flow data effectively reflected the respiratory flow and statistically correlated with the results from standard polysomnography sensors. Therefore, analyzing RIP flow utilizing an RIP sensor is considered a reliable method for respiratory event scoring.
机译:目的,建议呼吸感应体积描记术(RIP)作为替代呼吸道传感器,用于鉴定多核桃术中的每个呼吸暂停和次胃癌事件。使用该传感器,计算胸部和腹部(RIP和)的累积RIP结果和RIP和(RIP流程)的时间导出结果以跟踪呼吸流。然而,该传感器的有效性和计算的呼吸结果仍然不明确,并且对多瘤术中呼吸事件评分的验证研究很少见。方法根据阻塞性睡眠呼吸暂停的严重程度选择二百个受试者。睡眠专家根据单盲研究基于RIP流数据重新评估呼吸事件。在每个RIP流程和多仪表数据集中进行统计分析。结果从RIP流程评分的所有呼吸事件都与具有多核摄影标准传感器鉴定的呼吸事件强烈相关,无论疾病严重程度如何。来自RIP流动的大多数呼吸参数趋向于低估。从替代RIP传感器获得的RIP流程适用于基于接收器操作特性曲线诊断阻塞性睡眠呼吸暂停。结论来自RIP流量数据的呼吸事件有效地反映了呼吸流程,并与标准多面程传感器的结果进行统计相关。因此,利用RIP传感器分析RIP流量被认为是呼吸事件评分的可靠方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号